Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
>= 0 - <= 4 min
Remarks on result:
other: the sample was ignited within 2 min;after removal of ignition, the sample didn’t propagate combustion either by burning with flame or smouldering along 200 mm of the train within the 4 min.
Key result
Test procedure:
burning rate test over 100 mm length
Burning time:
>= 0 - <= 4 min
Conclusions:
The sample is not a highly flammable solid.

Description of key information

Key value for chemical safety assessment

Additional information

The sample  is not a highly flammable solid.

Justification for classification or non-classification