Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14 September 2017 - 19 October 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7220 (Boiling Point / Boiling Range)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Chemical structure
Reference substance name:
Fructose-1,6-Diphosphate, raw: Glucose anaerobically fermented by Saccharomyces cerevisiae, concentrated, phosphorylated
Molecular formula:
Molecular formula of the eponymous compound: C6H14O12P2
IUPAC Name:
Fructose-1,6-Diphosphate, raw: Glucose anaerobically fermented by Saccharomyces cerevisiae, concentrated, phosphorylated
Test material form:
solid
Details on test material:
Batch No.: 18224600

Results and discussion

Boiling point
Key result
Boiling pt.:
°C
Atm. press.:
1 013 hPa
Decomposition:
yes
Decomp. temp.:
ca. 100 °C

Any other information on results incl. tables

At approx. 100°C, an endothermic effect could be detected. No further endothermic or exothermic effects are detected. Due to the fact, that the measurements showed a very broad endothermic signal combined with a high noise in the DSC-signal, the endothermic effect as boiling was verified by an optical method. To do so, an additional measurement in a glass test tube was performed in the temperature range of -11 – 100 °C. At approx. -11 °C the test item is a solid and of caramel-like consistency. From approx. -11 to 100 °C no changes in the colour or the consistency could be observed. At approx. 100 °C the test item changes its colour, starts to melt and simultaneously the decomposition of the test item starts. According to the observations during the test in the glass test tube, the endothermic effect in the DSC measurements with open crucibles cannot be assigned to the boiling of the test item, because the test item starts to decompose at this temperature.

Applicant's summary and conclusion

Conclusions:
The test item Fructose-1,6-Diphosphate, raw: Glucose anaerobically fermented by Saccharomyces cerevisiae, concentrated, phosphorylated (EC no. 944-754-7) has no boiling point at atmospheric pressure (1001 hPa) up to its decomposition at approx. 100 °C as determined by differential scanning calorimetry and optical method according to Regulation EC No. 440/2008 Method A.2. and OECD Test Guideline 103 (1995).
Executive summary:

The test item Fructose-1,6-Diphosphate, raw: Glucose anaerobically fermented by Saccharomyces cerevisiae, concentrated, phosphorylated (EC no. 944-754-7) has no boiling point at atmospheric pressure (1001 hPa) up to its decomposition at approx. 100 °C as determined by differential scanning calorimetry and optical method according to Regulation EC No. 440/2008 Method A.2. and OECD Test Guideline 103 (1995).