Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Surface tension

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2 September 2016 - 31 January 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
Version / remarks:
27 July 1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.5 (Surface Tension)
Version / remarks:
31 May 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
plate method
Key result
Surface tension:
72.07 mN/m
Temp.:
19.5 °C
Conc.:
1 g/L

The surface tension of the negative control was determined with 73.17 mN/m at 18.7 °C, therefore, showing a difference of 0.26 % from the stated literature value. The difference lies within the accepted range of 1 % deviation from literature value.

Table 1 Measured values test item first series

 Measurement  Time  Mass  Surface Tension  Temperature
 No  s  g  mN/m  °C
 3.0 0.2941  71.74  19.5 
 2  6.0  0.2955 72.09    19.5 
 3 8.9   0.2955  72.09    19.5 
 4  12.0  0.2957  72.13    19.5 
 5  14.9  0.2950  71.96  19.5  
 6  18.0  0.2958  72.16   19.5 
 7  21.0  0.2965  72.33   19.5  
 8  24.0  0.2954   72.06   19.5 
 26.9   0.2955 72.09    19.5 
 10  30.0   0.2955  72.09  
Mean       72.07  
 Standard Deviation  0.15  

Table 2 Measured values test item second series

 Measurement  Time  Mass  Surface Tension  Temperature
 No  s  g  mN/m  °C
 3.0 0.2954 72.06 20.4
 2  5.9  0.2953 72.04     20.4  
 3 9.0   0.2954  72.06    20.4
 4  11.9  0.2954  72.06    20.4
 5  14.9  0.2955  72.09  20.4
 6  17.9  0.2954  72.13   20.4
 7  21.0  0.2957  72.06    20.4
 8 23.9  0.2954   72.06    20.4
27.0   0.2953 72.04    20.4
 10  29.9   0.2958  72.16  
Mean       72.08  
Conclusions:
The surface tension of an aqueous solution (1g/L) of the test item was determined as 72.07 ± 0.15 mN/m at 19.5 °C.
Executive summary:

A study was conducted according OECD TG 115 and EU method A.5 to determine the surface tension of an aqueous solution of the test item using the plate method. In the course of this study aqueous solutions were prepared containing 1 g/L test item in HPLC water. The test was performed with the help of K11HRX (Krüss) type tensiometer. The surface tension of the negative control HPCL water lay within the accepted range. The surface tension of an aqueous solution of the test item was determined as 72.07 ± 0.15 mN/m at 19.5 °C. One measurement was performed for verification (after 69 minutes). No significant changes and thus no significant dependence on time were observed. As these values were higher than 60 mN/m, the test item was classified as not surface active.

Description of key information

The surface tension of an aqueous solution of the test item was determined as 72.07 ± 0.15 mN/m at 19.5 °C.

Key value for chemical safety assessment

Surface tension:
72.07
in mN/m at 20°C and concentration in mg/L:
1 000

Additional information

A study was conducted according OECD TG 115 and EU method A.5 to determine the surface tension of an aqueous solution of the test item using the plate method. In the course of this study aqueous solutions were prepared containing 1 g/L test item in HPLC water. The test was performed with the help of K11HRX (Krüss) type tensiometer. The surface tension of the negative control HPCL water lay within the accepted range. The surface tension of an aqueous solution of the test item was determined as 72.07 ± 0.15 mN/m at 19.5 °C. One measurement was performed for verification (after 69 minutes). No significant changes and thus no significant dependence on time were observed. As these values were higher than 60 mN/m, the test item was classified as not surface active.