Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 Oct 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2015
Deviations:
no
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Constituent 1
Reference substance name:
9-Octadecenoic acid (Z)-, ester with oxybis[propanediol] (2:3)
EC Number:
289-147-1
EC Name:
9-Octadecenoic acid (Z)-, ester with oxybis[propanediol] (2:3)
Cas Number:
86088-80-4
Molecular formula:
not applicable, the substance is UVCB
IUPAC Name:
9-Octadecenoic acid (Z)-, ester with oxybis[propanediol] (2:3)

Results and discussion

Flash point
Flash point:
> 300 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: No flash point at up to testing instrument upper limit temperature (300 °C).

Any other information on results incl. tables

Test condition

Temperature: 21 °C; Humidity: 60 %RH; Atmospheric pressure: 1013 hPa

Test quantity

4 mL

Heating time

2 min

Flash point by seta-flash closed-cup

Test number

1

Above 300 °C *

2

Above 300 °C *

Average

Above 300 °C

Correction of observed flash point by atmospheric pressure

- °C

*No flash point at 300 °C (Testing instrument upper limit temperature: 300 °C)

Applicant's summary and conclusion