Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02 February 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
non GLP
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
GLP compliance:
no
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Type:
log Pow
Partition coefficient:
> 6.5
Temp.:
30 °C
pH:
6
Details on results:
The test substance did not elute within the the retention range of the reference standards, therefore the logPow was not calculated but given a limit value LogPow of greater than 6.5 .

Retention Time and Known Partition Coefficient Values

Standard name

Mean Retention time

Mean Log Capacity Factor = Log k’

Log POWa

SodiumNitrate[MK1] 

1.88

 

0

Acetanilide

2.125

-0.8851

1

Toluene

4.24

0.0988

2.7

Naphthalene

5.175

0.2437

3.6

Biphenyl

7.085

0.4423

4

Phenanthrene

10.11

0.6412

4.5

DDT

23.31

1.0569

6.5


a) Values taken from OECD Guideline 117

regression line y= 0.3465x - 1.0215 (R² = 0.9416) calculated based on the measurements in this study

 

Conclusions:
The logKow of the substance is > 6.5
Executive summary:

In a study using the HPLC method, the test substance did not elute within the retention range of the reference standards, therefore the logPow was not calculated but given a limit value LogPow of greater than 6.5.

Description of key information

In a study using the HPLC method, the test substance did not elute within the retention range of the reference standards, therefore the logPow was not calculated but given a limit value of greater than 6.5.

Key value for chemical safety assessment

Log Kow (Log Pow):
6.5
at the temperature of:
30 °C

Additional information

30 °C was the temperature of the column