Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2007-02-26
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
GLP compliance:
yes (incl. QA statement)
Analytical monitoring:
no
Vehicle:
no
Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
- Name and location of sewage treatment plant where inoculum was collected: Sludge was taken from the activation basin of the ESN (Stadtentsorung Neustadt) sewage treatment plant, Im Altenschemel, 67435 NW-Laken-Speyerdorf
- Pretreatment: The sludge was washed with tap water three times, then centrifuged and re-suspended in tap water. 200 mL of the sludge were added to each test vessel.
- Initial biomass concentration: Dry matter in the test = 1518 mg suspended solids/L.
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
3 h
Post exposure observation period:
not applicable
Hardness:
no data
Test temperature:
20 +/- 2 deg C
pH:
no data
Dissolved oxygen:
no data
Salinity:
no data
Conductivity:
no data
Nominal and measured concentrations:
nominal: 1, 10, 100, 1000 mg/L
Details on test conditions:
TEST SYSTEM
- Test vessel: glass beakers
- Aeration: yes, approx 0.75 L/min
- No. of vessels per concentration (replicates): 2 for 1000 mg/L, 1 for 1-100 mg/L
- No. of vessels per control (replicates): 2
- No. of vessels per abiotic control (replicates):
- Sludge concentration (weight of dry solids per volume): 1518 mg/L
- Nutrients provided for bacteria: Synthetic sewage
- Biomass loading rate:
TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: tap water
OTHER TEST CONDITIONS
- Adjustment of pH: no
EFFECT PARAMETERS MEASURED: Respiration rate
TEST CONCENTRATIONS
- Spacing factor for test concentrations: 10
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Duration:
3 h
Dose descriptor:
NOEC
Effect conc.:
1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Details on results:
- Any observations (e.g. precipitation) that might cause a difference between measured and nominal values: No
- Coefficient of variation of oxygen uptake rate in control replicates: Maximum of 8%, which is below the recommended limit of 15%
Results with reference substance (positive control):
- Results with reference substance valid? yes, EC50 = 5.1 mg/L which is within the recommended range of 5-30 mg/L
Reported statistics and error estimates:
not applicable

The test item showed very little inhibition in the experiment. In the highest treatment (1000 mg/L) no inhibition could be detected. In the the lower treatments, inhibition values stayed below 5%. Therefore, these values were not attributed to an inhibitory effect of the test item.

Validity criteria fulfilled:
yes
Conclusions:
The 3-h EC50 > 1000 mg/L
The 3-h NOEC = 1000 mg/L
Executive summary:

The inhibitory effect of the test item on the respiration rate of activated sludge microorganisms was determined according to OECD TG 209. The test item was tested using 5 concentrations ranging from 1 to 1000 mg/L. Duration of the test was 3 hours. Activated sludge taken from a domestic sewage treatment plant was used as inoculum. After washing, the dry matter was determined as 3.79 g suspended solids/L, giving a concentration of 1.52 g suspended solids/L in the test.

3,5 -dichlorophenol was used as the reference item. Five concentrations were tested; an EC50 of 5.1 was determined, which lies within the range of 5 -30 mg/L.

At 1000 mg/L no inhibition occurred. Therefore the pre-test can be taken as a limit test.

3h NOEC = 1000 mg/L

3h EC50 > 1000 mg/L

Description of key information

3h NOEC = 1000 mg/L

3h EC50 > 1000 mg/L

Key value for chemical safety assessment

EC10 or NOEC for microorganisms:
1 000 mg/L

Additional information

The inhibitory effect of the test item on the respiration rate of activated sludge microorganisms was determined according to OECD TG 209. The test item was tested using 5 concentrations ranging from 1 to 1000 mg/L. Duration of the test was 3 hours. Activated sludge taken from a domestic sewage treatment plant was used as inoculum. After washing, the dry matter was determined as 3.79 g suspended solids/L, giving a concentration of 1.52 g suspended solids/L in the test.

3,5 -dichlorophenol was used as the reference item. Five concentrations were tested; an EC50 of 5.1 was determined, which lies within the range of 5 -30 mg/L.

At 1000 mg/L no inhibition occurred. Therefore the pre-test can be taken as a limit test.

3h NOEC = 1000 mg/L

3h EC50 > 1000 mg/L