First-aid measures

Emergency measure - Eyes: Rinse with water.
Emergency measure - Skin: Wash with large amounts of water and then with soap and
water for 15 minutes before rinsing. Moisten clothes and
remove immediately.
Emergency measure - Ingestion: Symptomatic treatment.

Fire-fighting measures

Recommended extinguishing agent: Not applicable. (When incinerated gives SiO2,C02,H2O).

Accidental release measures

Emergency measures in case of spillage: Product to be collected using absorbant material and
disposed of.

Handling and storage

Handling: When handling large quantities use rubber gloves Avoid
inhaling mist or vapour.

Storage: Keep in a well ventilated and dry area. Store in 6 litre
polyethylene cans, 30/60 litre steel drums with
polyethylene lining and removable heads, 216 litre steel
drum with a heat-cured coating and non-removeable head and
rolling hoops.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Not applicable GGVE/GGVS: 3.32c RID/ADR: 3.32c
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None known. Hydrolyses in water.

Disposal considerations

Industry - Possibility of recovery/recycling: Not possible due to application.

Industry - Possibility of neutralisation: Not applicable

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: Recommended method. When incinerated produces carbon oxides
and silicon dioxide smoke.

Industry - Possibility of destruction - water purification: Insoluble in water, removal from water by phase separation
is possible. Some hydrolysis will occur.

Public at large - Possibility of recovery/recycling: Not possible due to application.

Public at large - Possibility of neutralisation: Not applicable

Public at large - Possibility of destruction: controlled discharge: Not recommended.

Public at large - Possibility of destruction - incineration: Recommended method. When incinerated substance produces
carbon oxides and silicon dioxide smoke.

Public at large - Possibility of destruction - water purification: Insoluble in water, removal from water by phase separation
is possible. Some hydrolysis will occur.