Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
3 dec 2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 1523 (Determination of flash point - Closed cup equilibrium method)
GLP compliance:
no
Other quality assurance:
other: ISO 9001
Type of method:
equilibrium method closed cup
Specific details on test material used for the study:
batch 2319
Key result
Flash point:
57 °C
Atm. press.:
1 atm
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
With a flash point at 57°C, the thuya plicata essential oil is classified as a flammable liquid category 3.
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
3 dec 2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 1523 (Determination of flash point - Closed cup equilibrium method)
GLP compliance:
no
Other quality assurance:
other: ISO 9001
Type of method:
equilibrium method closed cup
Specific details on test material used for the study:
batch 24/11
Key result
Flash point:
58 °C
Atm. press.:
1 atm
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
With a flash point at 58°C, the thuya plicata essential oil is classified as a flammable liquid category 3.
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 jan 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 1523 (Determination of flash point - Closed cup equilibrium method)
GLP compliance:
no
Other quality assurance:
other: ISO 9001
Type of method:
equilibrium method closed cup
Specific details on test material used for the study:
batch 4984
Key result
Flash point:
56 °C
Atm. press.:
1 atm
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
With a flash point at 56°C, the thuya plicata essential oil is classified as a flammable liquid category 3.

Description of key information

Three tests have been made and showed the following results :

 test #  result of flash point (°C)  method  batch year of the test 
 test 1  57  ISO 1523  2319  2010
 test 2  58  ISO 1523  24/11  2010
 test 3  56  ISO 1523  4984  2018

Key value for chemical safety assessment

Flash point at 101 325 Pa:
56 °C

Additional information

The flash point of test item is comprised between 56°C and 58°C,, with a mean value at 57°C, so the essential is classified as a flammable liquid category 3.