EC number: 222-613-4 | CAS number: 3555-47-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Melting point / freezing point
Administrative data
Link to relevant study record(s)
- Endpoint:
- melting point/freezing point
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study without detailed documentation
- Qualifier:
- according to guideline
- Guideline:
- other: ISO 3015 Cloud point
- GLP compliance:
- no
- Remarks:
- ISO 9001:2008
- Melting / freezing pt.:
- < -50 °C
- Conclusions:
- A cloud point of < -50.0 °C was determined in a reliable study conducted according to an appropriate test protocol, and in compliance with ISO 9001:2008. The result is considered to be reliable.
- Endpoint:
- melting point/freezing point
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study without detailed documentation
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 102 (Melting point / Melting Range)
- Version / remarks:
- Pour point
- GLP compliance:
- no
- Remarks:
- ISO 9001:2008
- Type of method:
- pour point
- Melting / freezing pt.:
- < -50 °C
- Conclusions:
- A pour point of < -50.0 °C was determined in a reliable study conducted according to an appropriate test protocol, and in compliance with ISO 9001:2008. The result is considered to be reliable.
- Endpoint:
- melting point/freezing point
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study without detailed documentation
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 102 (Melting point / Melting Range)
- GLP compliance:
- no
- Remarks:
- ISO 9001:2008
- Type of method:
- differential scanning calorimetry
- Key result
- Melting / freezing pt.:
- < -80 °C
- Decomposition:
- no
- Conclusions:
- A melting point of < -80 °C was determined in a reliable study conducted according to an appropriate test protocol, and in compliance with ISO 9001:2008. The result is considered to be reliable.
Referenceopen allclose all
Time [min] |
Sample Temperature [°C] |
Observations |
0 (start) |
25 |
clear liquid |
8 |
22 |
clear liquid |
12 |
19 |
clear liquid |
18 |
16 |
clear liquid |
22 |
13 |
clear liquid |
25 |
10 |
clear liquid |
30 |
7 |
clear liquid |
34 |
4 |
clear liquid |
38 |
1 |
clear liquid |
43 |
-2 |
clear liquid |
46 |
-5 |
clear liquid |
50 |
-8 |
clear liquid |
55 |
-11 |
clear liquid |
60 |
-14 |
clear liquid |
64 |
-17 |
clear liquid |
67 |
-20 |
clear liquid |
70 |
-23 |
clear liquid |
73 |
-25 |
clear liquid |
76 |
-28 |
clear liquid |
79 |
-31 |
clear liquid |
83 |
-34 |
clear liquid |
86 |
-37 |
clear liquid |
89 |
-40 |
clear liquid |
93 |
-43 |
clear liquid |
96 |
-46 |
clear liquid |
101 |
-49 |
clear liquid |
107 |
-52 |
clear liquid |
115 |
-55 |
clear liquid |
125 |
-58 |
clear liquid |
Result Cloud point: |
< –50 °C (< 223 K) |
Time [min] |
Sample Temperature [°C] |
Observations |
0 (start) |
25 |
clear liquid |
8 |
22 |
clear liquid |
12 |
19 |
clear liquid |
18 |
16 |
clear liquid |
22 |
13 |
clear liquid |
25 |
10 |
clear liquid |
30 |
7 |
clear liquid |
34 |
4 |
clear liquid |
38 |
1 |
clear liquid |
43 |
-2 |
clear liquid |
46 |
-5 |
clear liquid |
50 |
-8 |
clear liquid |
55 |
-11 |
clear liquid |
60 |
-14 |
clear liquid |
64 |
-17 |
clear liquid |
67 |
-20 |
clear liquid |
70 |
-23 |
clear liquid |
73 |
-25 |
clear liquid |
76 |
-28 |
clear liquid |
79 |
-31 |
clear liquid |
83 |
-34 |
clear liquid |
86 |
-37 |
clear liquid |
89 |
-40 |
clear liquid |
93 |
-43 |
clear liquid |
96 |
-46 |
clear liquid |
101 |
-49 |
clear liquid |
107 |
-52 |
clear liquid |
115 |
-55 |
clear liquid |
125 |
-58 |
clear liquid |
Result Pour point: |
< –50 °C (< 223 K) |
Test |
Melting- / Freezing temperature |
1 |
< –80 °C |
2 |
< –80 °C |
Mean value: |
< –80 °C, < 193 K |
Approximate accuracy of the instrument: ± 0.5 K (up to 600K)
Description of key information
Melting point: <80.0 °C (OECD 102)
Key value for chemical safety assessment
- Melting / freezing point at 101 325 Pa:
- -80 °C
Additional information
Three measured melting point values from the same author (Haas, 2017) are available for the substance.
A melting point value of <-80.0°C at 1013 hPa was determined for the substance using a Differential Scanning Calorimetry (DSC) method in accordance with OECD Test Guideline 102. The value is considered to be reliable and is selected as key value. Additionally, a melting point of <-50.0°C at 1013 hPa was determined for the substance using a cloud point method in accordance with the ISO 3015 test method and a melting point of <-50.0°C at 1013 hPa was determined for the substance using a pour point method in accordance with the OECD Test Guideline 102.
All three studies were conducted in compliance with a known quality system (ISO 9001:2008).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.