Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
skin irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 September 2016 - 11 January 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
Version / remarks:
2015
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method B.46 (In Vitro Skin Irritation: Reconstructed Human Epidermis Model Test)
Version / remarks:
2009
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
diethyl 2-methylidenebutanedioate
EC Number:
607-321-0
Cas Number:
2409-52-1
Molecular formula:
C9H14O4
IUPAC Name:
diethyl 2-methylidenebutanedioate

In vitro test system

Test system:
human skin model
Cell type:
non-transformed keratinocytes
Details on animal used as source of test system:
Epi-200 SIT kits and MTT-100 assays diluent were purchased from MatTek Corporation (82105 Bratislava, Slovakia). EpiDerm™ tissues were shipped with cool packs on medium-supplemented agarose gels in a 24-well plate. On day of receipt the pre-incubation phase of the EpiDerm™ tissues started.
Justification for test system used:
The EpiDerm TM is an in vitro system recommended by the corresponding guideline.
Vehicle:
unchanged (no vehicle)
Details on test system:
RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: Epi-200-SIT Kit
- Tissue batch number: 23356
- Date of initiation of testing: 20 September 2016

TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: 37 °C for 35 minutes; room temperature for 25 minutes
- Temperature of post-treatment incubation: 37 °C

REMOVAL OF TEST MATERIAL AND CONTROLS
- Volume and number of washing steps: rinsed with DPBS at least 15 times
- Observable damage in the tissue due to washing: none

MTT DYE USED TO MEASURE TISSUE VIABILITY AFTER TREATMENT / EXPOSURE
- MTT concentration: 1 mg/mL
- Incubation time: 3 h
- Spectrophotometer: Versamax Molecular Devices, Softmax Pro
- Wavelength: 570 nm

NUMBER OF REPLICATE TISSUES: 3

NUMBER OF INDEPENDENT TEST SEQUENCES / EXPERIMENTS TO DERIVE FINAL PREDICTION: 1

PREDICTION MODEL / DECISION CRITERIA
- The test substance is considered to be irritant to skin (Category 2) if the mean relative tissue viability of three individual tissues is reduced ≤ 50% of the negative control
- The test substance is considered to be non-irritant to skin if the mean relative tissue viability of three individual tissues is reduced > 50% of the negative control
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
TEST MATERIAL
- Amount applied: 30 µL
Duration of treatment / exposure:
35 min at 37 °C + 25 min at room temperature
Duration of post-treatment incubation (if applicable):
25 h + 18 h
Number of replicates:
3

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
other: relative absorbance (%)
Run / experiment:
Tissue 1
Value:
100.5
Vehicle controls validity:
not examined
Negative controls validity:
valid
Positive controls validity:
valid
Irritation / corrosion parameter:
other: relative absorbance (%)
Run / experiment:
Tissue 2
Value:
127.2
Vehicle controls validity:
not examined
Negative controls validity:
valid
Positive controls validity:
valid
Irritation / corrosion parameter:
other: relative absorbance (%)
Run / experiment:
Tissue 3
Value:
108.5
Vehicle controls validity:
not examined
Negative controls validity:
valid
Positive controls validity:
valid
Other effects / acceptance of results:
OTHER EFFECTS:
- Visible damage on test system: no
- Direct-MTT reduction: no
- Colour interference with MTT: no

ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: yes
- Acceptance criteria met for positive control: yes
- Acceptance criteria met for variability between replicate measurements: yes

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item is not irritant to skin according to UN GHS and EU CLP regulation.
Executive summary:

This in vitro study was performed to assess the irritation potential of the test item by means of the Human Skin Model Test.

The test item passed the pre-tests for colour interference and direct MTT reduction. Consequently, additional tests with freeze-killed or viable tissues were not necessary.

The test met the required acceptability criteria.

After treatment with the test item the mean relative absorbance value did not decrease (112.1%) compared to the relative absorbance value of the negative control. This value does not affect the threshold for irritancy of ≤ 50%. Therefore, the test item is not considered to possess an irritant potential.