Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Done in accordance with standard testing method however not under GLP.
Justification for type of information:
The justification for read across is provided as an attachment in IUCLID Section 13.
Reason / purpose for cross-reference:
read-across: supporting information
Qualifier:
according to guideline
Guideline:
other: ASTM D-445
Principles of method if other than guideline:
kinematic viscosity measured using certified reference standards. Time determined for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer at a specified temperature.
GLP compliance:
no
Remarks:
Not specified
Type of method:
other: Not specified
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
5.2
Conclusions:
The measured viscosity is 5.2 mm2/s at 20°C.
Executive summary:

The measured kinematic viscosity of Isohexadecane is 5.2 mm2/s at 20°C (company data).

Description of key information

This data is being read across from the source study that tested Isohexadecane based on analogue read across. The justification for read across is provided as an attachment in IUCLID Section 13.

The reported kinematic viscosity of Isohexadecane is 5.2 mm2/s at 20°C (company data).

Key value for chemical safety assessment

Viscosity:
5.2 mm²/s (static)
at the temperature of:
20 °C

Additional information