Registration Dossier

Administrative data

Link to relevant study record(s)

Description of key information

Test item Chelat Zn(II)HBED is not highly flammable in accordance with test A.10. criteria.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

After applying (3 tests) the flame of burner the sample is combusted but only in the flame zone. The flame is not spread to the rest of the train. Application time of the ignition source: 30 s, 60 s, 120 s. Result is negative. Since the results are negative, it is not necessary to go to the next stage of determination.

Justification for classification or non-classification

The test material does not meet the criteria for classification and will not require labelling in accordance with European Regulation (EC) No. 1272/2008, amending Regulation EC No. 1907/2006 (REACH).