Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 September - 29 December 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: UN no. ST/SG/AC/Rev.5: Recommendations on the Transport of Dangerous Goods, Part III, Test N.1: "Test Method for Readily Combust
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
3-(2-CHLOROETHYL)-9-HYDROXY-2-METHYL-4H-PYRIDO[1,2-A]PYRIMIDIN-4-ONE HYDROCHLORIDE (1:1)
EC Number:
617-648-0
Cas Number:
849727-62-4
Molecular formula:
C11H11ClN2O2.HCl
IUPAC Name:
3-(2-CHLOROETHYL)-9-HYDROXY-2-METHYL-4H-PYRIDO[1,2-A]PYRIMIDIN-4-ONE HYDROCHLORIDE (1:1)
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
- Name of test material (as cited in study report): T002006
- Substance type: almost white to ochre solid
- Physical state: solid
- Analytical purity: 97.5%
- Lot/batch No.: I15BB0722
- Expiration date of the lot/batch: 2017-02-21
- Storage condition of test material: At room temperature (15-25°C)

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Any other information on results incl. tables

In contact with the flame of the gas burner the test item melted, burned with a blue orange flame and turned into a black residue. Grey smoke was observed. After removal of the ignition source, the flame extinguished within one second and no propagation of combustion of the test item was observed.

According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not readily combustible’ (i.e. ‘not flammable’).

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The preliminary screening test was performed for the determination of the flammability of JNJ-1692405-AAC (T002006).

No propagation of combustion of the test item along 200 mm length of the pile within 2 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered 'not readily combustible' (i.e. ‘not flammable’).