Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-02-08 until 2016-05-27
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Version / remarks:
2009
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
burning time (test type not further specified)
Remarks:
Pasty substances are spread on a noncombustible surface in the form of an unbroken train 250 mm in length with a cross-section of about l00 mm2. The pile was arranged across the draught in a fume cupboard.
Remarks on result:
other: The test item did not ignite

The Test Item did not ignite in either case during the preliminary test. Therefore, the substance is considered not to be highly flammable.

Interpretation of results:
other: non flammable
Conclusions:
The test item is non flammable.
Executive summary:

The determination of the flammability of the solid test item was performed according to UN N1 Method and GLP. No deviation from the guidelines was observed in the study.

The test item did not ignite in the preliminary test, so it is considered as non flammable.

Description of key information

The determination of the flammability of the solid test item was performed according to UN N1 Method and GLP. No deviation from the guidelines was observed in the study.

The test item did not ignite in the preliminary test, so it is considered as non flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The test item did not ignite in the preliminary test, so it is considered as non flammable.

Justification for classification or non-classification

Based on the results obtained in the key study (UN N1 method used), the test item is considered as non flammable