Administrative data

Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12th September -17th December 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study was conducted according to OECD and in accordance with GLP. The study material is well characterised

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method
Media:
soil

Test material

Constituent 1
Chemical structure
Reference substance name:
pentasodium 4-amino-3-[(1E)-2-(2,4-disulfonatophenyl)diazen-1-yl]-5-hydroxy-6-[(1E)-2-(4-nitro-2-sulfonatophenyl)diazen-1-yl]naphthalene-1,7-disulfonate
EC Number:
811-858-8
Cas Number:
2149571-68-4
Molecular formula:
C22 H11 N6 O18 S5 .5Na
IUPAC Name:
pentasodium 4-amino-3-[(1E)-2-(2,4-disulfonatophenyl)diazen-1-yl]-5-hydroxy-6-[(1E)-2-(4-nitro-2-sulfonatophenyl)diazen-1-yl]naphthalene-1,7-disulfonate
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Radiolabelling:
no

Study design

Test temperature:
A stock solution of the reference substance at a concentration of approximately 1 g/l in methanol was used. The stock solution was diluted to obtain an end solution of 30/70 (v/v) methanol/water. The blank solution for the reference substance was 30/70 (v/v) methanol/water.
Test temperature 35 +/- 1C

HPLC method

Details on study design: HPLC method:
EQUIPMENT
- Apparatus: Acquity UPLC system (Waters, Milford, MA, USA)
- Type: UPLC
- Type, material and dimension of analytical (guard) column: Acquity UPLC HSS Cyano, 100 mm  2.1 mm i.d.,
dp = 1.8 µm (Waters)

- Detection system: Acquity UPLC TUV detector (Waters)


MOBILE PHASES
- Type: 30/70 (v/v) methanol/water

- Experiments with additives carried out on separate columns: yes / no
- pH: Neutral
- Solutes for dissolving test and reference substances: Methanol




REFERENCE SUBSTANCES
- Identity: Acetanilide CAS 103-84-4

DETERMINATION OF RETENTION TIMES
- Quantity of test substance introduced in the column: 5 µl

- Quantity of reference substances:
- Intervals of calibration:

REPETITIONS
- Number of determinations: Duplicacte for referecne and test substances, single application for blank solutions.

Results and discussion

Adsorption coefficientopen allclose all
Type:
Koc
Value:
< 18
Temp.:
35 °C
Type:
log Koc
Value:
< 1.26
Temp.:
35 °C

Results: HPLC method

Details on results (HPLC method):
Not given in report

Any other information on results incl. tables

 Koc  Log Koc
 Test Substance  <1.8 x 101  <1.26

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Conclusions:
The HPLC method using soil-adsorption-reference data was applied for the determination of the adsorption coefficient (Koc) of K1600 black dye