Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Remarks:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
6/5/2016 - 6/5/2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Principles of method if other than guideline:
The flash point determination of Test item was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus.

GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
> 250 °C
Atm. press.:
972.4 hPa
Remarks on result:
other: No other details

Observation Table :

Method Details

Observations

Remarks if, any

Method

Closed cup method using Pensky-Martens Flash Point Apparatus

 

 

Principle of Flash point test

The flash point of a flammable liquid is the lowest temperature at which there will be enough flammable vapor to ignite when an ignition source is applied.

 

 

Type of method

·    Closed cup

 

 

Flash point apparatus

·    Abel’s flash pt apparatus

·    Pensky-Martens flash point apparatus

Pensky-Martens flash point apparatus

 

Quantity of chemical used

g/ml

 5 g

 

Ignition source

Gas lighter/flame

Gas lighter

 

Atmospheric pressure

hPa

972.4 hPa

 

Flash point (RESULT)

°C

Greater than 250 °C

 

Interpretation of results:
other: Non flammable
Conclusions:
The flash point determination of test substance was done following closed cup method using Pensky-Martens flash point apparatus. The flash point was determined to be greater than 250 degC at 972.4 hPa.
Executive summary:

The flash point determination of Test item  was done. The method is closed cup method using Pensky-Martens Flash Point Apparatus. The flash point of the test item was determined to be greater than 250°C at 972.4 hPa. Therefore, according to CLP regulation the chemical 3,4,5,6-tetrachloro-2-(1,4,5,8-tetrabromo-6-hydroxy-3-oxoxanthen-9-yl)benzoic acid(CAS No. 18472-87-2) was considered to be non-flammable as the flash point value is > 250 degree C.

Description of key information

The flash point determination of est substance  was done following closed cup method using Pensky-Martens flash point apparatus. The flash point was determined to be greater than 250 deg C at 972.4 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
250 °C

Additional information

The flash point determination of Test item  was done. The method is closed cup method using Pensky-Martens Flash Point Apparatus. The flash point of the test item was determined to be greater than 250°C at 972.4 hPa.Therefore, according to CLP regulation the chemical was considered to be non-flammable as the flash point value is > 250 degree C.