Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Cross-reference
Reason / purpose for cross-reference:
reference to same study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report date:
2014

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Qualifier:
according to guideline
Guideline:
other: UN N.1; “Test Method for Readily Combustible Solids”, 2009.
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
4-(2-{(E)-2-[(1E)-1-{(2E)-2-[1,1-dimethyl-3-(4-sulfobutyl)-1,3-dihydro-2H-benzo[e]indol-2-ylidene]ethylidene}-2-{methyl[(trifluoromethyl)sulfonyl]amino}-1H-inden-3-yl]vinyl}-1,1-dimethyl-1H-benzo[e]indolium-3-yl)butane-1-sulfonate compound with N,N-diethylethanamine (1:1)
EC Number:
940-889-0
Cas Number:
1770781-13-9
Molecular formula:
C51 H52 F3 N3 O8 S3 . C6 H15 N
IUPAC Name:
4-(2-{(E)-2-[(1E)-1-{(2E)-2-[1,1-dimethyl-3-(4-sulfobutyl)-1,3-dihydro-2H-benzo[e]indol-2-ylidene]ethylidene}-2-{methyl[(trifluoromethyl)sulfonyl]amino}-1H-inden-3-yl]vinyl}-1,1-dimethyl-1H-benzo[e]indolium-3-yl)butane-1-sulfonate compound with N,N-diethylethanamine (1:1)
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
97.85%, 0.87% water, green-brown powder

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
9 s

Any other information on results incl. tables

The flame of the gas burner did ignite the test substance pile. The test substance expanded, burned with a orange flame and turned into a black residue. Black smoke was observed. After removal of the ignition source, the flame extinguished after 9 seconds and no propagation of combustion was observed.

Applicant's summary and conclusion

Interpretation of results:
other: not highly flammable
Conclusions:
The preliminary screening test was performed for the determination of the flammability of CH03938.
No propagation of combustion of the test substance along 200 mm length of the pile within 4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test substance is considered ‘not highly flammable’.