Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
flammable gases
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
pyrophoric liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Endpoint:
pyrophoric solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
Endpoint:
self-heating substances / mixtures
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted for organic peroxides

Description of key information

Based on the study results, the molecular structure and experience in handling and use, the substance is not classified and labelled as flammable in contact with water, pyrophoric, self-reactive substance and self-heating substance according to Regulation (EC) No 1272/2008 (CLP).

 

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Flammability:

The test on the flammability (Regulation (EC) No 440/2008 method A.10) was not performed as the test item is a liquid. For liquids the primary value for ease of ignition is the flash point conducted using Method A9 ‘Flash Point Method’ of Council Regulation (EC) No 440/2008. The result of the Flash Point test is used to allocate a liquid substance into the appropriate flammability class. The flash point was determined to be 40 °C at 1013.25 hPa. Thus, the substance was classified as flammable liquid cat 3.

According to chapter 2.15 of the CLP regulation, organic peroxides are thermally unstable substances or mixtures, which can undergo exothermic self-accelerating decomposition. In addition, they can have one or more of the following properties:

(i) be liable to explosive decomposition;

(ii) burn rapidly;

(iii) be sensitive to impact or friction;

(iv) react dangerously with other substances.

An organic peroxide is regarded as possessing explosive properties when in laboratory testing the mixture (formulation) is liable to detonate, to deflagrate rapidly or to show a violent effect when heated under confinement.

The classification of an organic peroxide in one of the seven categories “Types A to G” is dependent on its detonation, thermal explosion and deflagrating properties, its response to heating and the concentration.

 

Flammability in contact with water:

Based on the molecular structure as well as experience in handling and use, the test substance shows no water reactive properties.

 

Pyrophoric properties:

Based on the molecular structure as well as experience in in handling and use the test substance shows no pyrophoric properties.

 

Self-heating substance

According to Guidance on information requirements and chemical safety assessment, R7a, Endpoint specific guidance, R.7.1.10.7, the UN Test method N.4, for self-heating substances and mixtures does not need to be conducted as the substance is classified as organic peroxide.

Justification for classification or non-classification

Classification, Labelling, and Packaging Regulation (EC) No 1272/2008
The available experimental test data are reliable and suitable for classification purposes under Regulation (EC) No 1272/2008. Based on the study results, the molecular structure and experience in handling and use, the substance is not classified and labelled as flammable in contact with water, pyrophoric, self-reactive substance and self-heating substance according to Regulation (EC) No 1272/2008 (CLP), as amended for the eighth time in Regulation (EU) No 2016/918. Based on the flash point the substance was classified as flammable liquid cat 3, according to Regulation (EC) No 1272/2008 (CLP), as amended for the eighth time in Regulation (EU) No 2016/918.