Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: No GLP study, but test procedure in accordance with generally accepted scientific standards and described in sufficient detail

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
no guideline followed
Deviations:
not applicable
Principles of method if other than guideline:
Thermogravimetric analysis was chosen as it determines the heat stability of a molecule.
GLP compliance:
no
Type of method:
other: TGA

Test material

Constituent 1
Chemical structure
Reference substance name:
sodium 4-[(4-chlorobenzoyl)amino]benzoate
EC Number:
807-461-4
Cas Number:
1489170-67-3
Molecular formula:
C14H9ClNNaO3
IUPAC Name:
sodium 4-[(4-chlorobenzoyl)amino]benzoate
Test material form:
not specified

Results and discussion

Melting / freezing point
Decomposition:
yes
Decomp. temp.:
435 °C
Sublimation:
no
Remarks on result:
other: the substance decomposes before melting

Any other information on results incl. tables

In both cases (air and nitrogen), the substance shows remarkably good thermal stability, with no weight loss up to 400 °C.

Applicant's summary and conclusion

Conclusions:
The substance decomposes before melting. The decomposition temperature of the test material has been determined to be 435 °C by TGA. The study was performed in accordance with generally accepted scientific standards and described in sufficient detail and therefore reliability of Klimisch 2 has been assigned.