Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove victim to fresh air. In the event of irritation seek
medical advice.
Emergency measure - Eyes: Rinse eyes for at least 15 minutes and seek immediate
medical attention.
Emergency measure - Skin: Wash skin with soap and water. If irritation occurs, seek
medical advice.
Emergency measure - Ingestion: Seek immediate medical attention

Fire-fighting measures

Recommended extinguishing agent: Water, foam, dry chemical, carbon dioxide.

Product arising from burning: Products of combustion may contain oxides of carbon,
nitrogen and chlorine containing compounds.

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing
apparatus must be worn.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.


Wear appropriate personal protective equipment conforming to
the relevant national or international standards as
mentioned in section 2.3.10.


Avoid dust formation by damping down with water. Absorb
spillages of solutions with a suitable inert material (eg
sand or soil). Carefully transfer the spillage to waste
containers, or use a sealed industrial vacuum machine.
Containers filled with waste material must be labelled in
the same way as the original containers.


Clean the spillage area with water and detergent. Avoid
directing washings to the open sewer.


Dispose of waste material by incineration in accordance with
local regulations.

Handling and storage

Handling: The substance should be stored, handled and used in
conditions of good industrial hygiene and in conformity with
any local regulations in order to avoid exposure by
ingestion, skin or eyes.


Engineering controls are necessary to reduce exposure to the
substance.


When exposure cannot be prevented or adequately controlled
appropriate personal protective equipment should be worn.
Such protective equipment should conform to the appropriate
international or national standards as follows;

Chemical protective gloves to Standard prEN374

Chemical resistant clothing to Standard EN368

Eye protection to Standard prEN166


When necessary appropriate respiratory protection should be
used. e.g. a dust mask conforming to EN149 FFP1.


The standards mentioned above should be regarded as a
minimum.

Storage: Store in a dry well-ventilated area, in the dark.


Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: 2 litre polyethylene bottle, containing ca. 500g net.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: See below
Transport: Avoid dropping or crushing the containers. In the event of
spillage, refer to special instructions / safety data.


Transport code: UN class 4, Division 4.1 Flammable solids,

Packing Group II or III
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion: There is a potential dust explosion hazard from this organic
powder.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment will be minimal. Recovery from
minor spillages or accidental discharge is not economically
or technically feasible, and such waste material will be
disposed of by incineration. In principle, it may be
possible to recover larger spillages or waste for normal use
of uncontaminated material for subsequent use.

Industry - Possibility of neutralisation: None known.

Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages of solutions mixed with
inert material (eg sand or soil) may be disposed of by
landfill at an authorised tip in accordance with local
regulations.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning
under controlled conditions at a licensed waste treatment
processor in accordance with local regulations. Stack gases
should be scrubbed, because noxious fumes (eg carbon and
nitrogen oxides and chlorine containing compounds) could be
formed.

Industry - Possibility of destruction - water purification: It is not recommended that the substance should be
discharged directly to the sewage system or the aqueous
environment.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.