Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
read-across based on grouping of substances (category approach)
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
KL2 due to read across
Justification for type of information:
Refer to section 13 of IUCLID for details on the category justification.
Reason / purpose for cross-reference:
read-across source
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Remarks:
(Pensky-Martens closed cup method)
Flash point:
188 °C
Atm. press.:
101.3 kPa

None

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point was found to be 188 ºC at 101.3 kPa.
Executive summary:

A study was conducted to determine the flash point of the read across substance, C8-18 and C18-unsatd. DEA, in accordance with ISO Method 2719 and EU Method A.9 using the standard Pensky-Martens closed cup method. The flash point was found to be 188 ºC at 101.3 kPa (Fraczak, 2010).

Description of key information

The flash point of the read across substance, C8-18 and C18-unsatd. DEA, was determined according to ASTM Method 6450-99, equivalent to EU Method A9, using the standard Pensky-Martens closed cup method (Fraczak, 2010).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
188 °C

Additional information