Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no

Test material

Constituent 1
Reference substance name:
Extract residues (coal), benzole fraction acid
EC Number:
298-725-2
EC Name:
Extract residues (coal), benzole fraction acid
Cas Number:
93821-38-6

Results and discussion

Flash point
Flash point:
< 0 °C
Remarks on result:
other: The pressure was not indicated

Applicant's summary and conclusion