Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Auto-flammability does not need to be conducted for solids that melt at <160°C.  Corfree is a solid (flake) melting at 135°C  (see chapter 4.2). Ec method A.9 is not applicable to solids. The hazard flammability is determined using EU method A.10 (see chapter 4.13).  Therefore, a test is not required according to REACh Annex VII, 7.12, column 2.

Key value for chemical safety assessment

Additional information

Auto-flammability does not need to be conducted for solids that melt at <160°C. Corfree is a solid (flake) melting at 135°C (see chapter 4.2). EC method A.9 is not applicable to solids. The hazard flammability is determined using EU method A.10 (see chapter 4.13). Therefore, a test is not required according to REACh Annex VII, 7.12, column 2.