Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
dissociation constant
Type of information:
(Q)SAR
Adequacy of study:
key study
Study period:
Not applicable
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a (Q)SAR model, with limited documentation / justification, but validity of model and reliability of prediction considered adequate based on a generally acknowledged source
Justification for type of information:
1. SOFTWARE
ACD/I-Lab Web Service

2. MODEL (incl. version number)
(I-Lab 2.0).

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
CCCCOC(=O)\C=C/C(=O)O

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
No data

5. APPLICABILITY DOMAIN
No data

6. ADEQUACY OF THE RESULT
The predicted dissociation constant was 3.34 ± 0.10 using ACD/I-Lab Web Service (I-Lab 2.0). In the partition coefficient study, the mobile phase was adjusted to pH 2.2 so the test item was tested in a predominantly non-ionized form.
Cross-reference
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04 May 2012 and 13 August 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Type:
log Pow
Partition coefficient:
1.39
Temp.:
30 °C
pH:
2.2
Details on results:
Preliminary estimate
The log10 Pow was calculated to be: 2.40
The full KOWWIN calculation is presented in Appendix 1 (Attachment 2 - KOWWIN calculation).
Definitive test
Typical Chromatography can be found in Attachment 3 - Typical Chromatography.

Calibration

The retention times of the dead time and the retention times, capacity factors (k'-) and log10 Pow values for the reference standards are shown in the following tables:

Table 1.

Dead Time

Retention Time (mins)

Mean Retention Time (mins)

Injection 1

Injection 2

Thiourea

1.613

1.618

1.616

Table 2.

Standard

Retention Time (mins)

Mean Retention Time (mins)

Capacity Factor (k’)

Log10 k’

Log10Pow

Injection 1

Injection 2

2-Butanone

2.240

2.240

2.240

0.386

-0.413

0.3

Benzyl alcohol

2.877

2.877

2.877

0.78

-0.108

1.1

Benzonitrile

3.411

3.411

3.411

1.111

4.58 x 10-2

1.6

Benzene

7.293

7.293

7.293

3.514

0.546

2.1

Toluene

12.770

12.765

12.767

6.902

0.839

2.7

Naphthalene

19.835

19.835

19.835

11.277

1.05

3.6

Phenanthrene

58.669

58.669

58.669

35.313

1.55

4.5

Partition coefficient of sample

The retention times, capacity factor and log10 Pow value determined for the sample are shown in the following table:

Table 3.

Injection

Retention Time (mins)

Capacity Factor (k)

Log10K’

Log10Pow

1

3.562

1.21

8.08 x 10-2

1.39

2

3.562

1.21

8.08 x 10-2

1.39

Mean log10 Pow: 1.39

Partition coefficient: 24.4

Conclusions:
The partition coefficient of the test item has been determined to be 24.4, log10 Pow 1.39.
Executive summary:

An investigation was carried out to assess the partition coefficient of the test material, using the HPLC method, designed to be compatible with Method A8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.

The partition coefficient of the test item has been determined to be 24.4, log10 Pow 1.39.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
the dissociation constant was predicted using ACD/I-Lab Web Service (I-Lab 2.0).
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Butyl hydrogen maleate
EC Number:
213-116-3
EC Name:
Butyl hydrogen maleate
Cas Number:
925-21-3
Molecular formula:
C8H12O4
IUPAC Name:
(2Z)-4-butoxy-4-oxobut-2-enoic acid
Test material form:
other: liquid
Details on test material:
Description, Identification and Storage Conditions
Sponsor's identification : Butyl Hydrogen Maleate
Description : pale yellow liquid
Lot number : 120224
Purity : ≥95%
Date received : 20 March 2012
Expiry date : 30 March 2013
Storage conditions : room temperature in the dark

Results and discussion

Dissociating properties:
yes
Dissociation constant
No.:
#1
pKa:
3.34
Remarks on result:
other: The predicted dissociation constant was 3.34 ± 0.10 using ACD/I-Lab Web Service (I-Lab 2.0).

Applicant's summary and conclusion

Conclusions:
The predicted dissociation constant was 3.34 ± 0.10 using ACD/I-Lab Web Service (I-Lab 2.0).