Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
read-across based on grouping of substances (category approach)
Adequacy of study:
key study
Justification for type of information:
REPORTING FORMAT FOR THE CATEGORY APPROACH
Please see "Monoazo Yellow Pigments Category document" attached in section 13.2
Reason / purpose for cross-reference:
read-across source
Key result
Parameter:
other: Explosive
Remarks on result:
negative (not further specified)

Residual moisture:

The test item contains a residual moisture of 0.1 wt.-%, which was determined by drying the test item under vacuum.

Heating under confinement: Koenen-Test (UN-Test: 1(b)/2(b)

Tests with orifice plates with 1.0 and 2.0 mm diameter orifice were performed.

No.

Sample weight / g

Diameter orifice plate / mm

Reaction time t1 /s

Reaction time t2 /s

Reaction

Appearance of tube

1

15.64

1

22

>300

t1: Sparkling
t2: No reaction

0, Unchanged

2

15.39

1

26

>300

t1: Sparkling
t2: No reaction

0, Unchanged

3

15.37

1

24

>300

t1: Sparkling
t2: No reaction

0, Unchanged

4

15.36

2

18

>300

t1: Sparkling
t2: No reaction

0, Unchanged

5

15.44

2

20

>300

t1: Sparkling
t2: No reaction

0, Unchanged

6

15.33

2

17

>300

t1: Sparkling
t2: No reaction

0, Unchanged

t1: time to first reaction: e.g. burning
t2: time to main reaction: e.g. frizzling, bursting of tube

The test item shows no reaction with either an orifice plate with an orifice-diameter of 1 mm or 2 mm on heating under confinement.

Due to the chemical structure and the physical state (pure solid) an explosion for an orifice-diameter of 6 mm can be excluded.

Therefore, the Koenen-Test (UN-Test 1(b)/2(b)) of the test item shows no effect on heating under confinement with an orifice plate with an orifice diameter of 1 or 2 mm.

The assessment of the results with regard to test series 1 (b) was “-”.

The assessment of the results with regard to test series 2 (b) was “-”.

Mechanical sensitivity: Friction: BAM Friction Apparatus (UN-Test: 3(b)(i))

No explosion was observed within 6 tests using a 360 N loading.

The assessment of the results with regard to test series 3(b)(i) was “-”.

Mechanical sensitivity: Impact: BAM Fallhammer (UN-Test: 3(a)(ii))

No explosion was observed within 6 tests dropping the 10 kg mass from 0.50 m (50 J).

The assessment of the results with regard to test series 3(a)(ii) was “-”.

BAM Trautzl test (UN-Test F.3)

The assessment of the results was “No” (the expansion of the lead block was less than 10 cm³ per 10 g of sample).

Due to this result the result of the UN Gap Test 1(a)/2(a) is deemed to be “-”.

Time/Pressure Test (UN-Test 1(c)(i)/2(c)(i)/C.1)

The assessment of the results with regard to test series 1(c)(i) was “-” (gauge pressure of 2070 kPa was not reached: substance showed not the ability to deflagrate).

The assessment of the results with regard to test series 2(c)(i) was “-” (gauge pressure of 2070 kPa was not reached: substance showed no or slowly deflagration).

The assessment of the results with regard to test series C.1 was “No” (a pressure rise to 2070 kPa was not achieved).

Interpretation of results:
other: Non explosive
Conclusions:
UN-Transport regulations:
The test item does not have to be classified as explosive in Class 1 according to the UN-Transport Regulations.
GHS and EC 1272/2008 (CLP-Guideline), Annex 1: 2.1:
The test item does not have to be classified as explosive according to GHS and EC 1272/2008 (CLP-Guideline) Annex 1: 2.1..
EC 440/2008:
The test item has no explosive properties according to EC 440/2008, Part A, A.14.
Executive summary:

Due to the high decomposition energy (see section 4.2), it was tested whether the test item shows some effect on heating under confinement according to UN-Test series: 1(b)/2(b): Koenen-Test, is sensitive to impact according to UN-Test series: 3(a)(ii): BAM Fallhammer or is sensitive to friction according to UN-Test series: 3(b)(i): BAM friction apparatus (Class 1). Additionally, the BAM Trautzl-Test (UN-Test F.3) and the Time/Pressure-Test (UN-Test 1(c)(i)/C.1) were performed.

Heating under confinement: Koenen-Test (UN-Test: 1(b)/2(b)): The Koenen-Test (UN-Test 1(b)/2(b)) of the test item shows no effect on heating under confinement with an orifice plate with an orifice diameter of 1 or 2 mm. The assessment of the results with regard to test series 1 (b) was “-”. The assessment of the results with regard to test series 2 (b) was “-”.

Mechanical sensitivity: Friction: BAM Friction Apparatus (UN-Test: 3(b)(i)): The assessment of the results with regard to test series 3(b)(i) was “-”.

Mechanical sensitivity: Impact: BAM Fallhammer (UN-Test: 3(a)(ii)): The assessment of the results with regard to test series 3(a)(ii) was “-”.

BAM Trautzl test (UN-Test F.3): The assessment of the results was “No”. Due to this result the result of the UN Gap Test 1(a)/2(a) is deemed to be “-”.

Time/Pressure Test (UN-Test 1(c)(i)/2(c)(i)/C.1): The assessment of the results with regard to test series 1 (c) (i) was “-”. The assessment of the results with regard to test series 2 (c) (i) was “-”. The assessment of the results with regard to test series C.1 was “No”.

The test item has no explosive properties.

Description of key information

Key study: Based on read across category approach, the test item has no explosive properties according to CLP Regulation (EC) no. 1272/2008.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

Based on the available data, the substance is not classified as explosive according to CLP Regulation (EC) no. 1272/2008.