Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: UN no. ST/SG/AC.10/11/Rev.6 Paragraph 32.4.1: Non-Viscous Flammable Liquids
Version / remarks:
2015
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
2002
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D7094. Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
Version / remarks:
2012
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester
Dynamic viscosity of test material:
27 - 63 mPa s at 23 °C (ISO 3219)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: PX708164
- Expiration date of the lot/batch: 31 March 2018

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature container flushed with nitrogen
Key result
Flash point:
30 °C
Atm. press.:
1 019 hPa

 Preliminary Test

The estimated flash-point of the test item was 32°C.

Main Study

The results of the main study on the determination of the flash-point of the test item are given in Table 7.


Table 7 Main Study: Flash-point of the Test Item

Test

Flash-point

[°C]

Lowest flash-point

[°C]

1

30

30

2

30

 

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The flash-point of the test item was 30°C
Executive summary:

The closed cup method was applied for the determination of the flash-point of Setalux 7002 BX-55.

The flash-point of the test item was 30°C.

Description of key information

The closed cup method was applied for the determination of the flash-point of Setalux 7002 BX-55. The flash-point of the test item is 30°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
30 °C

Additional information