Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove patient from exposure.

Emergency measure - Eyes: Rinse with running water for at least 10 minutes.

Emergency measure - Skin: Wash with soap and water.

Emergency measure - Ingestion: Wash substance from mouth with water. Drink water (250 ml)

to dilute stomach contents.

Fire-fighting measures

Recommended extinguishing agent: Recommended extinguishing agents: Carbon dioxide, foam or

dry powder may be used.

Product arising from burning: Products arising from pyrolysis: Combustion products may

contain carbon and nitrogen oxides and toxic products

together with some soot.

Protective equipment: Protective equipment: Wear a self-contained breathing

apparatus.

Accidental release measures

Handling and storage

Handling: Do not inhale dust, use appropriate methods to avoid dust

inhalation. Avoid prolonged skin contact, wear polyethylene

gloves.

Storage: Store in sealed containers, label according to

classification.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Transport sealed containers, label according to
classification.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Other dangers: High dust concentrations may be explosive,

as is typical for other organic dusts.

Chemical reaction with water: Chemical reaction with water: None reported.

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery for reuse is possible by using solvent extraction

with tetrahydrofuran.

Industry - Possibility of neutralisation: None known.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: Recommended method. Incineration at an approved facility

equipped with waste gas treatment to remove nitrogen

oxides. Take appropriate precautions to avoid dust

formation.

Industry - Possibility of destruction - water purification: Recovery from water purification systems by filtration is

possible.

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain.