Administrative data

First-aid measures

Description of first aid measures                          

General information                                            

 Remove contaminated soaked clothing immediately and dispose of safely.                                                      

 In the event of symptoms refer for medical treatment.        

Inhalation                                                      

 No further relevant information available.                    

Skin contact                                                    

 In case of contact with skin wash off immediately with soap and water.                                                    

Eye contact                                                    

 In case of contact with eyes rinse thoroughly with plenty of water and seek medical advice.                                

Ingestion                                                      

 Do not induce vomiting.                                      

 Summon a doctor immediately.  

Most important symptoms and effects, both acute and delayed  

 No further relevant information available.                    

Indication of any immediate medical attention and special treatment needed                                            

 No further relevant information available.                                                    

Fire-fighting measures

Extinguishing media                                    

Suitable extinguishing media:                              

 water                                                    

 alcohol-resistant foam                                  

 dry powder                                              

 carbon dioxide                                          

Unsuitable extinguishing media:                            

 No further relevant information available.              

Special hazards arising from the substance or mixture  

 In the event of fire the following can be released:      

 Sulphurous oxides (SOx)

Advice for firefighters                        

Special protective equipment:                      

 Use breathing apparatus.                          

Addition information:                              

 Do not inhale explosion and/or combustion gases.                                    

Accidental release measures

Personal precautions, protective equipment and emergency procedures                                                    

 Avoid contact with eyes and skin.                              

Environmental precautions                                    

 Do not discharge into the drains/surface water/groundwaters.    

Methods and material for containment and cleaning up          

 Take up with absorbent material.                                

 e.g. general-purpose binder                                    

 Dispose of absorbed material in accordance with the regulations.

Handling and storage

Precautions for safe handling                                

 No special measures necessary.                                

Information about fire and explosion protection:                

 No special measures necessary.                                

General information:                                            

 Do not eat, drink, smoke or sniff while working.              

 Wash hands before breaks and at the end of work.              

Conditions for safe storage, including any incompatibilities

Requirements to be met by storerooms and receptacles:            

 No special measures necessary.                                

Information about storage in one common storage facility:        

 No further relevant information available.  

Further information about storage conditions:    

 No further relevant information available.    

Specific end use(s)                          

 No further relevant information available.                        

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
not required
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Appropriate engeneering controls                                        

 No further relevant information available.                            

Personal protective equipment                                            

Eye protection (EN 166)                                                  

 goggles                                                                

Hand protection (EN 374)                                                

 For permanent contact gloves made of the following materials are suitable (Permeation according to EN 374 Part 3: Level 6):            

 Nitrile rubber (NBR) gloves                                            

 The exact penetration time must be obtained from the manufacturer of the protective gloves and has to be observed. The                  

 determination of penetration times according to EN 374 part III is not performed under practical conditions. Therefore a maximum      

 wearing time, which corresponds to 50% of the penetration time, is recommended.                                      

Skin protection (EN 465)                                

 protective clothing                                  

Respiratory protection (EN 141/149)                    

 not required                                          

General protective measures / hygiene measures          

 Observe the usual precautions when handling chemicals.      

Stability and reactivity

Reactivity                                

 No further relevant information available.  

Chemical stability                        

 No further relevant information available.  

Possibility of hazardous reactions        

 No further relevant information available.  

Conditions to avoid                      

 Protect from heat/overheating.              

Incompatible materials                    

 Reactions with alkalies.                    

 Reactions with acids.                        

Hazardous decomposition products          

 None with proper handling and storage.      

Disposal considerations

Waste treatment methods                                      

Recommendation:                                                  

Can be taken to an incineration plant, if relevant regulations in force are being observed and, if necessary, after consulting  

the waste disposal agency, respectively the relevant authorities.

Do not allow product to reach the drainage.                      

Contaminated packaging                                            

Recommendation:                                                  

Contaminated packaging should be emptied as far as possible and may be reused after appropriate cleansing.