Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 August 2000 - 6 October
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Value:
2
Number of fragments:
0
Remarks on result:
negative (not further specified)
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Value:
6
Number of fragments:
0
Remarks on result:
negative (not further specified)
Key result
Test series:
UN Test series 2
Method:
UN Test 2 (b): Koenen test
Parameter:
other: heated for 300 seconds
Value:
0
Result:
negative, no explosion
Key result
Test series:
UN Test series 3
Method:
UN Test 3 (a) (ii): BAM Fallhammer
Parameter:
other: qualitative observation
Value:
0
Result:
negative, not sensitive to detonative shock
Remarks on result:
no ignition, explosion, self-heating or visible decomposition
Key result
Test series:
UN Test series 3
Method:
UN Test 3 (b) (i): BAM friction apparatus
Parameter:
other: Qualitative observation
Value:
0
Result:
negative, no explosion
Remarks on result:
other: No signs of explosion but observed slight decomposition
Interpretation of results:
GHS criteria not met
Conclusions:
The test substance is not explosive.
Executive summary:

A Koenen test apparatus was used for determination of sensitivity to heat (flame), a fall hammer for determination of sensitivity to shock and a friction test apparatus for determination of sensitivity to friction.

All results were considered to be negative.

The test substance is not explosive.

Description of key information

A Koenen test apparatus was used for determination of sensitivity to heat (flame), a fall hammer for determination of sensitivity to shock and a friction test apparatus for determination of sensitivity to friction.

All results were considered to be negative.

The test substance is not explosive.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

Following testing all results were considered to be negative. Therefore test substance is considered not to be explosive.