Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard OECD test guidelines
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
GLP compliance:
no
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
4.08
Temp.:
25 °C
Remarks on result:
other: other details not available

 Test substance  K  log K  log Pow by generalized calibration curve  Mean of log Pow± S.D
  tR1  3.14 2.339   0.369  4.084  4.082 ± 0.003   
   tR2 3.136  2.334  0.368  4.08
Conclusions:
The octanol water partition coefficent of test chemical was determined to be 4.08 by HPLC method.
Executive summary:

The octanol water partition coefficent of test chemical was determined according to OECD guideline no 117 using reverse phase HPLC method. In this method reference substances used were namely Butanone, Benzene, Biphenyl, Toluene, Ethylbenzene, n-Butylbenzene, Naphthalene, Allyl phenyl ether having log Pow between range 0.3 -4.6 and calibration graph was prepared and by using this graph, the octanol water partition coefficent of test chemical was determined to be 4.08.

Description of key information

The octanol water partition coefficient of test chemical was determined according to OECD guideline no 117 using reverse phase HPLC method. In this method reference substances used were namely Butanone, Benzene, Biphenyl, Toluene, Ethylbenzene, n-Butylbenzene, Naphthalene, Allyl phenyl ether having log Pow between range 0.3 -4.6 and calibration graph was prepared. By using this graph, the octanol water partition coefficient of test chemical was determined to be 4.08.

Key value for chemical safety assessment

Log Kow (Log Pow):
4.08
at the temperature of:
25 °C

Additional information

The octanol water partition coefficient of test chemical was determined according to OECD guideline no 117 using reverse phase HPLC method. In this method reference substances used were namely Butanone, Benzene, Biphenyl, Toluene, Ethylbenzene, n-Butylbenzene, Naphthalene, Allyl phenyl ether having log Pow between range 0.3 -4.6 and calibration graph was prepared. By using this graph, the octanol water partition coefficient of test chemical was determined to be 4.08.