Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
short-term toxicity to fish
Type of information:
experimental study
Adequacy of study:
key study
Study period:
between 8th May 2009 and 10th March 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies which did not affect the quality of relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 203 (Fish, Acute Toxicity Test)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
Pellicer
IUPAC Name:
Pellicer
Details on test material:
Test Substance: Pellicer
Lot number: 01-09-12
Expiry date: 2011/1/12
Appearance: White powder
Purity/Assay: 91 %
Storage conditions: Room temperature

Sampling and analysis

Analytical monitoring:
yes

Test solutions

Vehicle:
not specified

Test organisms

Test organisms (species):
Danio rerio (previous name: Brachydanio rerio)

Study design

Test type:
semi-static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
96 h

Results and discussion

Effect concentrations
Duration:
96 h
Dose descriptor:
LC50
Effect conc.:
9.39 mg/L
Nominal / measured:
meas. (initial)
Conc. based on:
test mat.
Basis for effect:
mortality (fish)
Remarks on result:
other: 95% CL (8.87 - 9.94 mg/L)

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Remarks:
All validity criteria were met during this study.
Conclusions:
The test material produced an LC 50 of 9.39 mg/L (95% Confidence limits = 8.87 - 9.94 mg/L), under semi static conditions using OECD guideline 203. The test material will not be classified though as the substance is readily biodegradable.
Executive summary:

The test material produced an LC50 value of 9.39 mg/L, under semi static conditions using OECD guideline 203. The test material is not classified according to regulation (EC) No 1272/2008 as the substance is readily biodegradable. The study is provided as supporting information and is in addition to the requirements of the standard Annex VII requirements. The study was conducted in compliance with regulatory requirements in China.