Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-06-12
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
7.82
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
4.838

Table 1: Result

Temperature

20°C

40°C

1strun

264.35

507.22

2ndrun

263.84

507.56

3rdrun

263.91

507.47

4thrun

264.60

507.59

5thrun

263.92

507.48

Mean value of flow time [s]

264.124

507.464

Hagenbach correction [s]

0.024

0.041

Corrected flow time [s]

264.100

507.423

Viscosimeter constant [mm2s-2]

0,02961

0,009535

Kinematic viscosity [mm2s-1]

7.820

4.838

 

Conclusions:
Kinematic viscosity values of 7.82 at 20°C and 4.838 at 40°C were determined for the substance uisng a relevant test method. The result is considered to be reliable.

Description of key information

Viscosity: 7.820 mm2/s at 20°C, 4.838 mm2/s at 40°C (OECD 114)

Key value for chemical safety assessment

Viscosity:
7.82 mm²/s (static)
at the temperature of:
20 °C

Additional information

Kinematic viscosity values of 7.820 mm2/s at 20°C and 4.838 mm2/s at 40°C were determined for the substance using a capillary viscometer in accordance with OECD 114 test method and in compliance with known quality system (ISO 17025). The result is considered to be reliable.