Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Qualifier:
according to guideline
Guideline:
other: Commission Regulation (EU) 2016/266 adopted 7 December 2015 amending Regula-tion EC No. 440/2008, Method A.24 “Partition Coefficient (N-OCTANOL/WATER), HIGH PERFORMANCELIQUID CHROMATOGRAPHY (HPLC) METHOD
GLP compliance:
no
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

1
Chemical structure
Reference substance name:
Dimethyloctadecyl(3-sulphopropyl)ammonium hydroxide
EC Number:
236-124-9
EC Name:
Dimethyloctadecyl(3-sulphopropyl)ammonium hydroxide
Cas Number:
13177-41-8
Molecular formula:
C23H49NO3S
IUPAC Name:
dimethyl(octadecyl)(3-sulfopropyl)azanium hydroxide
Test material form:
solid

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
> 6.5
Temp.:
25 °C
pH:
> 5 - < 6
Details on results:
The chromatogram of the test substance gave one peak with a retention time of 13.923 min (mean). As the retention time of the test substance (13.923 min) lay above the retention time of 4,4'-DDT (8.360 min) and so outside of the calibrated range, a log Pow could only be extrapolated. The calculated log POW of the test item is 6.8 ± 0.0.

Applicant's summary and conclusion

Conclusions:
The log Pow is reported with >6.5 at 25°C. The retention time of the test substance is outside the range of the calibration.
Executive summary:

The study was performed using a HPLC with a C18 column. Seven reference items with different retention times and thiourea for the determination of the dead time were used to produce a calibration curve, since retention time on hydrophobic columns and POW are correlated.

The chromatogram of the test item Stearyl Sulfobetaine gave one peak with a retention time of 13.923 min (mean). As the retention time of the test item (13.923 min) lay above the retention time of 4,4'-DDT (8.360 min) and so outside of the calibrated range, a log Pow could only be extrapolated. The calculated log POW of the test item is 6.8 ± 0.0.