Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: Modified Bowes-Cameron Cage test as per section 14.5.5 of the United Nations Transport of Dangerous Goods -Recommendations
Deviations:
yes
Remarks:
The sample was placed into an oven already at 140°C.
GLP compliance:
yes
Specific details on test material used for the study:
Substance ID: DPX-JE874-221
Purity: Not reported
Key result
Remarks on result:
no self ignition observed under the test conditions
Conclusions:
Negative for self ignition
Executive summary:

The modified Bowes-Cameron Cage test as per section 14.5.5 of the United Nations Transport of Dangerous Goods - Recommendations was used to determine the self-ignition properties of the test substance.


In the 100 mm cubic container test the internal temperature of the test substance gradually increased to the oven temperature of 140°C and remained at that temperature for the duration of the 24-hour test. Since a negative result was obtained for this test, the test involving the 25 mm cube was not required.


The test substance gave a negative reaction for tests conducted in a 100 mm mesh cube at 140°C.

Description of key information

Per UN transport recommendations

Key value for chemical safety assessment

Additional information

Negative reaction for tests conducted in a 100 mm mesh cube at 140°C