Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2020
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Done in accordance with ASTM D93-07 testing method, however not in GLP
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
(SASOL 2060)
GLP compliance:
no
Type of method:
other: Pensky martens closed cup
Flash point apparatus:
other: Tanaka – Pensky martens closed cup AMP-7
Key result
Flash point:
44 °C
Atm. press.:
1 atm
Conclusions:
The measured flash point is 44°C at 1 atm.
Executive summary:

The flash point of Hydrocarbons, C9 -C11, n-alkanes, <2% aromatics , measured in accordance with method ASTM D93 is 44°C at 1 atm.

Description of key information

The flash point of Hydrocarbons, C9 -C11, n-alkanes,<2% aromatics, according to the ASTM D 93-07 method, is 44°C at 1 atm.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
44 °C

Additional information