Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
8 November 2019 to 27 November 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch number of test material: E0016-912
- Expiration date of the lot/batch: 18 September 2020
- Purity: 82 %
Contact with:
powdered cellulose
Key result
Sample tested:
test mixture as specified
Remarks:
2:1 sample-to-cellulose ratio
Parameter:
preliminary test
Remarks on result:
other: The pile charred but failed to ignite
Sample tested:
reference mixture as specified
Remarks:
mixture of barium nitrate + cellulose (10 to 90 % by weight)
Parameter:
maximum burning rate
Result:
1.212 mm/s
Remarks on result:
other: The pile burnt with a green/orange flame with orange sparks, grey smoke and left grey/black charred remains
Key result
Sample tested:
test mixture as specified
Remarks:
Mixture of test item + cellulose (10 to 90 % by weight)
Parameter:
maximum burning rate
Result:
0 mm/s
Remarks on result:
mixture does not ignite and burn

MAIN TEST RESULTS:

- Reference Mixtures:

% Barium Nitrate Observations Burning Time (s) Burning Rate (mm/s)
10 The pile burnt with an orange flame with some orange sparks, grey smoke and left black charred remains 247 0.810
20 The pile burnt with an orange flame with some orange sparks, grey smoke and left black/grey charred remains 240 0.833
30 The pile burnt with an orange/green flame with some orange sparks, grey smoke and left black/grey charred remains 231 0.866
40 The pile burnt with an orange/green flame with some orange sparks, grey smoke and left black/grey charred remains 205 0.976
50 The pile burnt with a green/orange flame with orange sparks, grey smoke and left grey/black charred remains 192 1.042
60 The pile burnt with a green/orange flame with orange sparks, grey smoke and left grey/black charred remains 165 1.212
70 The pile burnt with a green/orange flame with orange sparks, grey smoke and left white/grey charred remains 208 0.962
80 The pile ignited but self-extinguished without propagating combustion - -
90 The pile ignited but self-extinguished without propagating combustion - -

- Sample Mixtures:

% Test Item Observations Burning Time (s) Burning Rate (mm/s)
10 The pile burnt with a small blue flame which self-extinguished after propagating combustion over 1 cm in 19 seconds leaving black charred remains - -
20 The pile ignited with a small blue flame which self-extinguished without propagating combustion - -
30  The pile ignited with a small blue flame which self-extinguished without propagating combustion - -
40  The pile ignited with a small blue flame which self-extinguished without propagating combustion - -
50  The pile ignited with a small blue flame which self-extinguished without propagating combustion - -
60  The pile ignited with a small blue flame which self-extinguished without propagating combustion - -
70 The pile failed to ignite - -
80  The pile failed to ignite - -
90  The pile failed to ignite - -
Interpretation of results:
GHS criteria not met
Conclusions:
The test item was determined not to have oxidising properties as the test item:cellulose sample mixtures failed to propagate combustion.
Executive summary:

The oxidising properties of the test item was determined using a procedure designed to be compatible with Method A.17 Oxidising Properties (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008. The test item was determined not to have oxidising properties as the test item:cellulose sample mixtures failed to propagate combustion; therefore, the test item is not classified based on GHS criteria.

Description of key information

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification

The oxidising properties of the test item was determined using a procedure designed to be compatible with Method A.17 Oxidising Properties (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008. The test item was determined not to have oxidising properties as the test item:cellulose sample mixtures failed to propagate combustion; therefore, the test item is not classified based on GHS criteria.