Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25 September 2020 to 19 November 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
yes
Remarks:
The final composition of the reference item mix was 40.5 %THF/59.5 % aqueous phase instead of 40 %/60 %. This was considered uncritical because the difference is negligible (for comparison: the maximum allowed error of the used pipettes is 0.3 %).
GLP compliance:
yes
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
ca. 1.1 - ca. 9.95
Temp.:
25 °C
pH:
ca. 7
Remarks on result:
other:
Remarks:
The log KOW value of the test item X-21415 must be stated as < 1.1 - > 9.95. Calculation of a weighted mean value is not possible, because the log KOW values of a large percentage of the test item mass can only be extrapolated (C.p. details in paragraph "Any other information on results incl. tables")

The chromatograms of the test item gave 51 peaks distributed over 30 mass traces. With the calibration function log k versus log KOW, the corresponding log KOW values of the major peaks were calculated. The peaks were named according to the total number of carbon atoms in the side chains with suffixes “a”, “b” or “c” where different isomers were resolved.

Component

Mean Retention Time

[min]

Mean Peak Area

[counts*min]

Relative Peak area

[%]

Log KOW

± Standard Deviation

 

 

 

C14

0.695

1357337

0.4

< 1.10

C16

0.719

107667883

30.5

< 1.10

C18

0.747

79161192

22.4

< 1.10

C20

0.786

45459065

12.9

< 1.10

C22

0.832

30777332

8.7

1.37 ± 0.000

C24a

0.752

92174

< 0.1

< 1.10

C24b

0.884

4033330

1.1

1.93 ± 0.000

C26a

0.793

122126

< 0.1

< 1.10

C26b

0.884

183718

< 0.1

1.93 ± 0.000

C28

0.845

201709

< 0.1

1.51 ± 0.074

C30a

0.886

18862

< 0.1

1.94 ± 0.033

C30b

1.038

184555

< 0.1

3.10 ± 0.113

 

C30c

1.081

229514

< 0.1

3.36 ± 0.019

 

C32a

1.118

9546787

2.7

3.56 ± 0.000

 

C32b

1.207

6932968

2.0

3.98 ± 0.018

 

C34a

1.239

13062896

3.7

4.12 ± 0.015

 

C34b

1.363

8134423

2.3

4.59 ± 0.014

 

C36a

1.386

12107151

3.4

4.67 ± 0.033

 

C36b

1.550

6196770

1.8

5.18 ± 0.021

 

C38a

1.564

9294014

2.6

5.21 ± 0.011

 

C38b

1.780

3882593

1.1

5.75 ± 0.015

 

C40a

1.241

57335

< 0.1

4.13 ± 0.027

 

C40b

1.780

4431731

1.3

5.75 ± 0.015

 

C40c

2.053

1678616

0.5

6.30 ± 0.012

 

C42a

1.382

44370

< 0.1

4.66 ± 0.033

 

C42b

2.038

1821782

0.5

6.27 ± 0.019

 

C42c

2.396

682146

0.2

6.86 ± 0.006

 

C44a

1.566

31887

< 0.1

5.22 ± 0.018

 

C44b

2.361

622870

0.2

6.81 ± 0.015

 

C44c

2.809

228170

< 0.1

7.40 ± 0.009

 

C46a

1.782

18464

< 0.1

5.75 ± 0.009

 

C46b

2.729

116411

< 0.1

7.31 ± 0.014

 

C46c

Not evaluated (only 2 peaks in 3 determinations)

 

C48a

2.865

291745

< 0.1

7.47 ± 0.015

 

C48b

3.249

100530

< 0.1

7.88 ± 0.017

 

C50a

3.364

565381

0.2

7.99 ± 0.022

 

C50b

3.829

165895

< 0.1

8.40 ± 0.014

 

C52a

3.931

704659

0.2

8.49 ± 0.027

 

C52b

4.550

156187

< 0.1

8.93 ± 0.011

 

C54a

4.618

659788

0.2

8.98 ± 0.042

 

C54b

5.384

122101

< 0.1

9.44 ± 0.002

 

C56a

5.367

525654

0.1

9.43 ± 0.029

 

C56b

6.396

77637

< 0.1

> 9.94 ± 0.010

 

C58

6.461

354312

0.1

> 9.95

 

C60

7.555

138663

< 0.1

> 9.95

 

C62

9.105

49118

< 0.1

> 9.95

 

C64

Not detectable

 

C66

10.479

137282

< 0.1

> 9.95

 

C68

12.062

199368

< 0.1

> 9.95

 

C70

Not evaluated (only 1 peak in 3 determinations)

 

C72

Not detectable

 

                 

These values are the means ± standard deviations of three independent determinations

Peaks of components C14, C16, C18, C20, C24a and C26a eluted between the dead time marker and the first reference substance with a literature log KOW of 1.1. Therefore, the corresponding log KOW values should be stated as < 1.1 for these components. Peaks C58, C60, C62, C66 and C68 eluted after the last reference substance with a literature log KOW of 9.95. Therefore, the corresponding log KOW values should be stated as > 9.95.

Components C46c, C64, C70 and C72 were not detectable in at least one out of three inde-pendent determinations and were therefore not evaluated.

The peaks of components C14, C16, C18, C20, C24a and C26a correspond to a relative peak area of 66.3 %, The peaks of components C58, C60, C62, C66 and C68 correspond to a relative peak area of 0.2 %. The remaining peaks with log KOW values in the range 1.1 – 9.95 represent 33.4 % of the total peak area.

As a consequence, the log KOW value of the test item X-21415 must be stated as < 1.1 - > 9.95. Calculation of a weighted mean value is not possible, because the log KOW values of a large percentage of the test item mass can only be extrapolated.

Conclusions:
The log KOW value of the test item X-21415 must be stated as < 1.1 - > 9.95. Calculation of a weighted mean value is not possible, because the log KOW values of a large percentage of the test item mass can only be extrapolated.
Executive summary:

Peaks of components C14, C16, C18, C20, C24a and C26a eluted between the dead time marker and the first reference substance with a literature log KOW of 1.1. Therefore, the corresponding log KOW values should be stated as < 1.1 for these components. Peaks C58, C60, C62, C66 and C68 eluted after the last reference substance with a literature log KOW of 9.95. Therefore, the corresponding log KOW values should be stated as > 9.95.
Components C46c, C64, C70 and C72 were not detectable in at least one out of three independent determinations and were therefore not evaluated.
The peaks of components C14, C16, C18, C20, C24a and C26a correspond to a relative peak area of 66.3 %, the peaks of components C58, C60, C62, C66 and C68 correspond to a relative peak area of 0.2 %. The remaining peaks with log KOW values in the range 1.1 – 9.95 represent 33.4 % of the total peak area. As a consequence, the log KOW value of the test item X-21415 must be stated as < 1.1 – > 9.95. Calculation of a weighted mean value is not possible, because the log KOW values of a large percentage of the test item mass can only be extrapolated.
It was not possible to use a reference item with log KOW value < 1.1 because of interfering peaks at short retention times originating from the phenylalkane reference items. 

Description of key information

Log Kow was determined in OECD Guideline 117. The chromatograms of the test item gave 51 peaks distributed over 30 mass traces. The log KOW value of the test item X-21415 must be stated as < 1.1 –> 9.95. Calculation of a weighted mean value is not possible, because the log KOW values of a large percentage of the test item mass can only be extrapolated.

Key value for chemical safety assessment

Additional information