Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22-03-2007 to 27-07-2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study performed under GLP. All relevant validity criteria were met.
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
inspected: November 2006 ; signature: February 2007
Type of method:
oscillating densitimeter
Type:
relative density
Density:
ca. 0.902 other: dimensionless
Temp.:
20 °C
Remarks on result:
other: Temperature: 20 ± 0.5 °C
Type:
density
Density:
0.902 g/cm³
Temp.:
20 °C
Remarks on result:
other: Temperature: 20 ± 0.5 °C

Determination 1: 0.902 at 20°C

Determination 2: 0.902 at 20°C

Determination 3: 0.902 at 20°C

Conclusions:
The relative density of the test item was determined to be 0.902 at 20 ± 0.5 °C.
Executive summary:

The relative density was determined using EU Method A.3 and OECD Method 109 oscillating densitimeter method under GLP. The relative density of the test item has been determined to be 0.902 at 20 ± 0.5 °C.

Description of key information

Relative Density: 0.902 at 20 ± 0.5 °C, EU Method A.3 – oscillating densitimeter method, 2007

Key value for chemical safety assessment

Relative density at 20C:
0.902

Additional information

Key study : EU Method A.3, 2007 : The relative density was determined using EU Method A.3 and OECD Method 109 oscillating densitimeter method under GLP. The relative density of the test item has been determined to be 0.902 at 20 ± 0.5 °C.