Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27.03.2020 - 07.04.2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020
Report date:
2020

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
Version / remarks:
2017
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
(2R,2'R)-3,3'-disulfanediylbis(2-((S)-2-aminopropanamido)propanoic acid)
Cas Number:
115888-13-6
Molecular formula:
C12H22N4O6S2
IUPAC Name:
(2R,2'R)-3,3'-disulfanediylbis(2-((S)-2-aminopropanamido)propanoic acid)
Test material form:
solid

Test animals / tissue source

Species:
other: bovine eyes
Details on test animals or tissues and environmental conditions:
TISSUES
- Source: Slaughterhouse (Vitelco, -'s Hertogenbosch, The Netherlands)
- Age at study initiation: young cattle
- Transport: in physiological saline under cooled conditions

Test system

Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent positive control
yes, concurrent negative control
Amount / concentration applied:
The test item was applied directly on the corneas in such a way that the cornea was completely covered (308.4 to 339.3 mg).
Duration of treatment / exposure:
240 +/- 10 minutes at 32 +/- 1°C
Duration of post- treatment incubation (in vitro):
90 +/- 5 minutes at 32 +/- 1°C
Number of animals or in vitro replicates:
3
Details on study design:
SELECTION AND PREPARATION OF CORNEAS :
The eyes were checked for unacceptable defects, such as opacity, scratches, pigmentation and neovascularization by removing them from the physiological saline and holding them in the light. Those exhibiting defects were discarded.
The isolated corneas were stored in a petri dish with cMEM (Eagle’s Minimum Essential Medium containing 1% (v/v) L-glutamine and 1% (v/v) Fetal Bovine Serum). The isolated corneas were mounted in a corneal holder (one cornea per holder) with the endothelial side against the O-ring of the posterior half of the holder. The anterior half of the holder was positioned on top of the cornea and tightened with screws. The compartments of the corneal holder were filled with cMEM of 32 +/- 1°C. The corneas were incubated for the minimum of 1 hour at 32 +/- 1°C.

QUALITY CHECK OF THE ISOLATED CORNEAS :
After the incubation period, the medium was removed from both compartments and replaced with fresh cMEM. Opacity determinations were performed on each of the corneas using an opacitometer. The opacity of each cornea was read against a cMEM filled chamber, and the initial opacity reading thus determined was recorded. Corneas that had an initial opacity reading higher than 7 were not used. Three corneas were selected at random for each treatment group.

NEGATIVE CONTROL USED : Physiological saline

POSITIVE CONTROL USED : 20% (w/v) Imidazole solution prepared in physiological saline

TREATMENT METHOD:
The medium from the anterior compartment was removed and 750 µL of the negative control and 20% (w/v) Imidazole solution (positive control) were introduced onto the epithelium of the cornea. The test item was weighed in a bottle and applied directly on the corneas in such a way that the cornea was completely covered. The holder was slightly rotated, with the corneas maintained in a horizontal position, to ensure uniform distribution of the solutions over the entire cornea. Corneas were incubated in a horizontal position for 240 +/- 10 minutes at 32 +/- 1°C.

REMOVAL OF TEST SUBSTANCE
After the incubation the solutions and the test item were removed and the epithelium was washed at least three times with MEM with phenol red. Possible pH effects of the test item on the corneas were recorded. Each cornea was inspected visually for dissimilar opacity patterns. The medium in the posterior compartment was removed and both compartments were refilled with fresh cMEM and the opacity determinations were performed.

METHODS FOR MEASURED ENDPOINTS:
- Corneal opacity: The opacity of a cornea was measured by the diminution of light passing through the cornea. The light was measured as illuminance (I = luminous flux per area, unit: lux) by a light meter (OP-KIT). The change in opacity for each individual cornea (including the negative control) was calculated by subtracting the initial opacity reading from the final post-treatment reading. The corrected opacity for each treated cornea with the test item or positive control was calculated by subtracting the average change in opacity of the negative control corneas from the change in opacity of each test item or positive control treated cornea. The mean opacity value of each treatment group was calculated by averaging the corrected opacity values of the treated corneas for each treatment group.
- Corneal permeability: passage of sodium fluorescein dye measured with the aid of microtiter plate reader (OD490) .

SCORING SYSTEM: In Vitro Irritancy Score (IVIS)

DECISION CRITERIA: Decision criteria as indicated in the TG was used.

Results and discussion

In vitro

Resultsopen allclose all
Irritation parameter:
in vitro irritation score
Run / experiment:
Mean
Value:
0.2
Negative controls validity:
valid
Positive controls validity:
valid
Irritation parameter:
cornea opacity score
Run / experiment:
Mean
Value:
-0.3
Negative controls validity:
valid
Positive controls validity:
valid
Irritation parameter:
fluorescein retention score
Run / experiment:
Mean
Value:
0.031
Negative controls validity:
valid
Positive controls validity:
valid
Other effects / acceptance of results:
The negative control responses for opacity and permeability were less than the upper limits of the laboratory historical range indicating that the negative control did not induce irritancy on the corneas. The mean in vitro irritancy score of the positive control (20% (w/v) Imidazole) was 133 and within two standard deviations of the current historical positive control mean. It was therefore concluded that the test conditions were adequate and that the test system functioned properly.
The test item did not induce ocular irritation through both endpoints, resulting in a mean in vitro irritancy score of 0.2 after 240 minutes of treatment.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
In conclusion, since N,N´-Di-L-Alanyl-L-Cystine / (L-Ala-L-Cys)2 induced an IVIS ≤ 3, no classification is required for eye irritation or serious eye damage.