Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14 JAN 2002 - 21 MAR 2002
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
Guideline 92/69/EEC, 1992
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Flash point:
90.5 °C
Atm. press.:
1 013.3 hPa

Preliminary measurement:

Volume : 2.0 mL

Flash point: 91.1 °C Measured

Barometric pressure 1019.8 hPa

Main Test:

The following table shows the results of the principal test. Temperatures, where ignition (+) was detected and where not (-).

Temperature [°C] Ignition +/-   Barometric pressure [hPa]  Flashpoint [°C] (corrected) 

86.0

- 1019.8   
87.0 - 1019.8   
88.0 -  1019.8    

89.0

-  1019.8    
90.0  1019.8    
91.0 +  1019.8  

 90.83

89.0 -  1019.8    
90.0 -  1019.8    
91.0 +  1019.8    90.83
90.0 +  1019.8    89.83
 89.0  1019.8    
 89.0  -   1019.8   
 89.0  -   1019.8   
 90.0  -   1019.8   
 91.0  +   1019.8   90.83

Mean flash point corrected to 1013 hPa: 90.5 °C.

Interpretation of results:
other: EU GHS criteria not met
Conclusions:
The flash point at atmospheric pressure (1013.3 hPa) is: 90.5 °C.
Executive summary:

The flash point was tested according to EU Method A.9 in a GLP study with a Setaflash apparatus. The flash point at atmospheric pressure (1013.3 hPa) is: 90.5 °C.

Description of key information

The flash point was tested according to EU Method A.9 in a GLP study with a Setaflash apparatus. The flash point at atmospheric pressure (1013.3 hPa) is 90.5 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
90.5 °C

Additional information