Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 26 April 2018 and 08 May 2018.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study is considered to be a reliability 1 as it has been conducted according to EU Method A.9 (Flash-Point) using the equilibrium closed cup method and in compliance with GLP.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Specific details on test material used for the study:
Identification: FRET 15-0735
Appearance/Physical state: Clear colorless liquid
Storage conditions: Room temperature in the dark
Flash point:
165 °C
Atm. press.:
100.8 kPa

Results of the flashpoint determination are shown in the following table:

Temperature (ºC)

Observations

21.0

No flash.

26.0

No flash.

31.0

No flash.

36.0

No flash.

41.0

No flash.

46.0

No flash.

51.0

No flash.

56.0

No flash.

61.0

No flash.

66.0

No flash.

71.0

No flash.

71.0 (fresh sample)

No flash.

76.0

No flash.

81.0

No flash.

86.0

No flash.

91.0

No flash.

96.0

No flash.

101.0 (fresh sample)

No flash.

106.0

No flash.

111.0

No flash.

116.0

No flash.

121.0

No flash.

126.0

No flash.

131.0

No flash.

136.0

No flash.

141.0

No flash.

146.0

No flash.

151.0

No flash.

151.0 (fresh sample)

No flash.

156.0

No flash.

161.0

No flash.

166.0

A blue flash spread across the sample cup.

166.0 (fresh sample)

A blue flash spread across the sample cup.

161.0 (fresh sample)

No flash.

161.0 (fresh sample)

No flash.

162.0 (fresh sample)

No flash.

 

Temperature (ºC)

Observations

163.0 (fresh sample)

No flash.

164.0 (fresh sample)

No flash.

165.0 (fresh sample)

A blue flash spread across the sample cup.

165.0 (fresh sample)

A blue flash spread across the sample cup.

163.0 (fresh sample)

No flash.

Atmospheric pressure: 100.8 kPa
Observed flash point: 165.0°C
Corrected flash point: 165.1°C

Interpretation of results:
GHS criteria not met
Conclusions:
The Flash point of FRET 15-0735 was determined using an reliable GLP study according to EU Method A.9 (Flash-Point) using the closed cup method . The Flash point of the substance is 165°C ± 2 °C at atmospheric pressure (100.8 kPa).

Executive summary:

The Flash point of FRET 15-0735 at atmospheric pressure (100.8 kPa), is 165°C ± 2 °C according to EU Method A.9 (Flash-Point) using the closed cup method.

Description of key information

The Flash point of FRET 15-0735 at, atmospheric pressure (100.3 kPa), is 165°C ± 2°C according to EU Method A.9 (Flash-Point) using the closed cup method. The substance is not considered a flammable liquid because the flash point exceeds 60°C based on the classification criteria for flammable liquids (Annex I of CLP Section 2.6).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
165 °C

Additional information