Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Take the patient into the fresh air.

Emergency measure - Eyes: Rinse with water for at least 15 minutes and call a doctor

if irritation persists.

Emergency measure - Skin: Wash the skin with water.

Emergency measure - Ingestion: Call a doctor.

Fire-fighting measures

Recommended extinguishing agent: Use water, carbon dioxide or dry powder to extinguish a

fire. Above 200 deg C decomposition may produce hydrogen

chloride gas. Wear a self-contained breathing apparatus and

skin protection when fighting a fire. NOx, acid fumes

(HF/HCL), and smoke likely

Accidental release measures

Emergency measures in case of spillage: Sweep up spills. Avoid contaminating sewers and other water

systems.

Handling and storage

Handling: Avoid contact, ingestion and inhalation of the dust. Ensure

suitable ventilation. Wear safety glasses, rubber gloves,

protective clothing and a suitable respirator.

Storage: Storage temperature: 10-40 deg C

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: No special precautions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None.

Disposal considerations

Industry - Possibility of recovery/recycling: The substance may be reused if it is not contaminated.

Industry - Possibility of neutralisation: Not applicable.

Industry - Possibility of destruction: controlled discharge: No

Industry - Possibility of destruction - incineration: This is possible using an incinerator that is designed for

solids and that has gas absorption equipment for hydrogen

chloride. Incinerate at temperatures above 950 deg C for a

period of at least 2 seconds. NOx, HF and smoke likely

Industry - Possibility of destruction - water purification: No

Public at large - Possibility of recovery/recycling: The substance will not enter the public domain. Therefore

this section is not applicable.