Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to aquatic algae and cyanobacteria

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
toxicity to aquatic algae and cyanobacteria
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Justification for type of information:
For this endpoint a one-to-one read across was performed to a chemical that forms an identical common degradation product. The relevant study was performed according to GLP and the methods applied are fully compliant with OECD TG 201. A detailed read across justification is provided in chapter 13 of this dossier.
Reason / purpose for cross-reference:
read-across source
Key result
Duration:
72 h
Dose descriptor:
EC50
Effect conc.:
68 mg/L
Nominal / measured:
meas. (geom. mean)
Conc. based on:
other: common degradation product
Basis for effect:
growth rate
Remarks on result:
other: 95% CL: 61 - 73 mg/L
Key result
Duration:
72 h
Dose descriptor:
EC10
Effect conc.:
33 mg/L
Nominal / measured:
meas. (geom. mean)
Conc. based on:
other: degradation product
Basis for effect:
growth rate
Remarks on result:
other: 95% CL: 23 - 55 mg/L
Validity criteria fulfilled:
yes
Conclusions:
For this endpoint a one-to-one read across was performed to a chemical that forms an identical common degradation product. The 72 h EC50s of the common degradation product are 43, 45, and 68 mg/L for biomass, growth rate and yield, respectively. Further a NOEC of 20 mg/L was obtained.
Endpoint:
toxicity to aquatic algae and cyanobacteria
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Analytical Support: 20 September 2017 and 04 June 2018, Definitive Assay: 29 May 2018 and 01 June 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 201 (Alga, Growth Inhibition Test)
GLP compliance:
yes (incl. QA statement)
Analytical monitoring:
yes
Details on sampling:
At the start of the test (0 hours), 10 mL samples of freshly prepared test media were taken from the control and each test media preparation flask for chemical analysis.
At 72 hours, inoculated replicate test vessels at each treatment level were pooled and sampled. Samples (10 mL) of each were taken for chemical analysis.
Vehicle:
yes
Test organisms (species):
Pseudokirchneriella subcapitata (previous names: Raphidocelis subcapitata, Selenastrum capricornutum)
Details on test organisms:
The axenic strain of Pseudokirchneriella subcapitata (CCAP 278/4) was obtained from a concentrated liquid slope culture from the Culture Collection of Algae and Protozoa (CCAP), SAMS Research Services Ltd., Oban, UK.
On receipt from the CCAP, the slope culture was stored in the fridge at 2 8 °C. A typical shelf life for each slope was 8 months, after which the slopes were discarded.
Test type:
static
Water media type:
freshwater
Limit test:
no
Total exposure duration:
72 h
Test temperature:
23.1 – 23.5°C
pH:
7.47-9.78
Nominal and measured concentrations:
Concentrations in [mg/L]
--------------------------------------------------------------------------------------
Nominal Measured concentration
--------------------------------------------------------------------------------------
0 h 72 h (old media) Geometric mean
--------------------------------------------------------------------------------------
6.25 6.87 5.89 6.36
12.5 13.1 11.5 12.3
25 25.9 15.0 20
50 52.9 42.2 47
100 111 82.1 96
--------------------------------------------------------------------------------------
Details on test conditions:
Test Procedures

Range-finding Test
A range-finding test was conducted at nominal test concentrations of 0.10, 1.0, 10 and 100 mg/L. A control group was also included. Duplicate test vessels were prepared for the control and each test concentration. Chemical analysis of the test preparations was not conducted during the range-finding test.

Solubility/Stability Trial
Following completion of the range-finding test, initial trials were conducted to determine the solubility and stability of the test substance in test media. Initial trials showed highly variable analytical results.
During analytical method development it was realised that the test substance was highly unstable in the test media. Further work indicated that the DT50 was <1 hour. As recommended by the OECD Series on Testing and Assessment, No. 23 (2000); (Guidance Document on Aquatic Toxicity Testing of Difficult Substances and Mixtures), the testing was therefore conducted on the degradation product 6-hydroxy-5-oxo-5,6-dihydronaphthalene-1-sulfonic acid.
A solubility/stability trial was therefore conducted to determine the solubility and stability of the degradation product in test media over the duration of the test.
Test concentrations of 100 mg/L were prepared in duplicate in EC medium. The preparations were left under laboratory conditions for ca 2 hours to fully degrade. Samples were taken for analysis from each preparation at 0 hours. From each preparation vessels were prepared with and without algae and then left under test conditions for 72 hours after which further samples were taken for chemical analysis.

Definitive Test
Based on the results of the range-finding tests, the definitive test was conducted at nominal test concentrations of 6.25, 12.5, 25, 50 and 100 mg/L.

Preparation of Test Medium
At the start of the test, 99.97 mg of test substance was dissolved in 1000 mL of EC medium to give the 100 mg/L test concentration. The preparation was left at room temperature for approximately 2 hours to degrade. Serial dilutions were prepared in EC media to give the 50, 25, 12.5 and 6.25 mg/L test concentrations. A control group was prepared by adding EC medium only to the control vessels.

Appearance of Test Media
The appearance, colour and behaviour of the test substance in the test media were recorded at the start and end of the test.

Test Vessel Preparation
The test vessels were sterile autoclaved glass 250 mL Erlenmeyer (conical) flasks, into which 100 mL of the appropriate control or test media was added.
Three test vessels were prepared for each test concentration as well as six control vessels (EC medium only). Each test and control vessel was inoculated with sufficient Pseudokirchneriella subcapitata cells to achieve a starting algae cell concentration of 1 x 104 cells/mL. An additional inoculated vessel was prepared for the control and each test concentration for initial water quality analysis. The shape and general condition of the algae in the culture was assessed by microscopic observations prior to use.
A media blank (EC media only) was prepared to establish background counts on each sampling occasion. Background counts were subtracted from the cell counting results for each of the inoculated test vessels. The resulting cell counts were then used to calculate the yield and the corresponding specific growth rates.

Test Vessel Sampling
At approximately 24-hour intervals after the start of the incubation period, pre determined volumes of test media were removed from each incubated test vessel, and transferred to individually identified cell counting vials. The contents of each vial were diluted to a 10 mL final volume with an electrolyte solution. The cell density of the vial contents was then determined using a particle counter (Z2 Coulter Counter®).

Environmental Conditions
All flasks were loosely-capped and incubated in a temperature and light controlled incubator. The vessels were shaken at ca 100 rpm under conditions of constant light (4440 to 8880 Lux), using florescent lights, emitting white light across the visible portion of the spectrum (400 - 700 nm).
At the start of the test, the pH of freshly prepared test media was determined. The pH in each test vessel was also determined at the end of the test.
The temperature was set within the range 21 to 24 °C. The temperature was recorded continuously using a digital temperature logger.
The light intensity within the incubator was monitored at the start and end of the test at four separate locations within the test area.
Reference substance (positive control):
yes
Remarks:
Potassium dichromate
Key result
Duration:
72 h
Dose descriptor:
EC10
Effect conc.:
33 mg/L
Nominal / measured:
meas. (geom. mean)
Conc. based on:
other: degradation product
Basis for effect:
growth rate
Remarks on result:
other: 95%CL: 23-55 mg/L
Key result
Duration:
72 h
Dose descriptor:
EC50
Effect conc.:
43 mg/L
Nominal / measured:
meas. (geom. mean)
Conc. based on:
other: degradation product
Basis for effect:
biomass
Duration:
72 h
Dose descriptor:
EC50
Effect conc.:
68 mg/L
Nominal / measured:
meas. (geom. mean)
Conc. based on:
other: degradation product
Basis for effect:
growth rate
Duration:
72 h
Dose descriptor:
EC50
Effect conc.:
45 mg/L
Nominal / measured:
meas. (geom. mean)
Conc. based on:
other: degradation product
Basis for effect:
other: Yield
Duration:
72 h
Dose descriptor:
NOEC
Effect conc.:
20 mg/L
Nominal / measured:
meas. (geom. mean)
Conc. based on:
other: degradation product
Basis for effect:
other: biomass / yield / growth rate
Details on results:
Based on geometric mean measured concentrations, the 72-hour EyC50 and ErC50 values were calculated to be 45, and 68 mg/L, respectively
Results with reference substance (positive control):
Yield LCL(mg/L)- UCL (mg/L) Area Under Curve LCL(mg/L)- UCL (mg/L) Growth Rate LCL(mg/L)- UCL (mg/L)
EC10 (mg/L) 0.0810 0.0118 – 0.773 0.0706 0.0192 – 0.650 0.791 0.349 – 1.43
EC20 (mg/L) 0.449 NA – 1.03 0.416 NA – 0.874 1.16 0.963 – 1.49
EC50 (mg/L) 1.19 0.514 – 2.01 1.21 0.504 – 1.93 1.93 1.69 – 2.44
Validity criteria fulfilled:
yes
Conclusions:
Based on geometric mean measured concentrations, the 72-hour EyC50 and ErC50 values are 43, 45, and 68 mg/L for biomass, growth rate and yield, respectively. Further a NOEC of 20 mg/L was obtained.

Description of key information

For this endpoint information from a structural similar compound is available. The study for this similar compound was performed according to GLP and the methods applied are fully compliant with OECD TG 201. See chapter 13 report for a more detailed justification.

From this read across the following effect levels which are relevant for C&L values are obtained:

EC50 (72h , growth rate) = 68 mg/L

EC10 (72h, growth rate) = 33 mg/L

Key value for chemical safety assessment

EC50 for freshwater algae:
68 mg/L
EC10 or NOEC for freshwater algae:
33 mg/L

Additional information