Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 2017-03-01 to 2017-03-01
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: United Nations Recommendations on the Transport of Dangerous Goods Manual of Tests and Criteria - Sixth revised edition (2015) Method N.4 (Part III, Section 33.3.1.6)
GLP compliance:
yes (incl. QA statement)

Test material

1
Chemical structure
Reference substance name:
Copper, [29H,31H-phthalocyaninato(2-)-N29,N30,N31,N32]-, [[3-(cyclohexylamino)propyl]amino]sulfonyl derivs.
EC Number:
309-627-7
EC Name:
Copper, [29H,31H-phthalocyaninato(2-)-N29,N30,N31,N32]-, [[3-(cyclohexylamino)propyl]amino]sulfonyl derivs.
Cas Number:
100545-46-8
Molecular formula:
C32H16-τN8Cu.(SO3)m.(SO3H)p.(C9H19N2SO2)O.(C9H20N2SO2)n
IUPAC Name:
Copper, [29H,31H-phthalocyaninato(2-)-N29,N30,N31,N32]-, [[3-(cyclohexylamino)propyl]amino]sulfonyl derivs.
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: In darkness at room temperature


Results and discussion

Relative self-ignition temperature (solids)
Key result
Remarks on result:
no self ignition observed under the test conditions

Any other information on results incl. tables

Assay No. 1

Duration of the test :24 hours

Observations/results

The edge length of the cubic sample container was 25 mm.

The internal temperature in the oven was 140 °C. The minimum temperature and maximum temperature were 141 °C.

The minimum temperature of the test item was 136 °C and its maximum temperature was 141 °C.

At the start of the test, the test item was a blue homogeneous powder. At the end, the test item remained a blue homogeneous powder.

No self-ignition temperature of the test item was recorded and the temperature of the sample did not exceed the oven temperature by 60 °C (corrected value).

Assay No. 2

Duration of the test : 24 hours

Observations/results

The edge length of the cubic sample container was 100 mm.

The internal temperature in the oven was 140 °C. The minimum temperature was 139 °C and maximum temperature was 140 °C.

The minimum temperature of the test item was 105 °C and its maximum temperature was 230 °C.

At the start of the test, the test item was a blue homogeneous powder. At the end, the test item became hard and remained blue.

A self-ignition temperature of the test item was recorded and the temperature of the sample exceeded the oven temperature by 60 °C (corrected value). As a consequence, a third assay was made with the test item in a 100 mm edge length sample cube at 100 °C as

the test item is to be carried in packaging of not more than 450 litre volumes (information provided by the Sponsor).

Assay No. 3

Duration of the test 24 hours

Observations/results

The edge length of the cubic sample container was 100 mm.

The internal temperature in the oven was 100 °C. The minimum temperature and maximum temperature were 141 °C.

The minimum temperature of the test item was 48 °C and its maximum temperature was 102 °C.

At the start of the test, the test item was a blue homogeneous powder. At the end, the test item remained a blue homogeneous powder.

No self-ignition of the test item was recorded and the temperature of the sample did not exceed the oven temperature by 60 °C.

Applicant's summary and conclusion

Conclusions:
Conclusion
The result is considered negative, the test item was not classified in division
Executive summary:

Conclusion

The result is considered negative, the test item was not classified in division