Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2003
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2003
Report date:
2003

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
GLP compliance:
yes (incl. QA statement)
Type of method:
shake-flask method to: flask method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
-0.7
Temp.:
20 °C
pH:
ca. 4.89

Applicant's summary and conclusion

Conclusions:
During the preliminary test, the log Pow of ucb 22060 was estimated to be -1.3. Therefore
the flask shaking method was chosen to conduct the main test.
During the main study, three tests were carried out, each in duplicate, with volume ratios of
both solvents of 1:1, 2:1 and 1:2. After equilibration the concentration of the test item was
determined in every phase by HPLC. The results of the individual measurements are
summarised in Table 3. The tabulated values represent rounded results, which were obtained
by calculation using the exact raw data. The log Pow was calculated for each of the six
vessels and was found to be in the range of -0.65 to – 0.67.
In order to check the anal~tcal work, the mass balance for each vessel was calculated, too,
and the recovery of the test item was found to be in the range of 97 YO to 99 Yo. Details are
given in Table 4. The tabulated results represent rounded-off values obtained by calculations
based on the exact raw data.
A typical chromatogram of a standard solution is given in Figure 3. A typical chromatogram of
an aqueous sample solution is given in Figure 4. A typical chromatogram of a sample
solution in n-octanol is given in Figure 5. The calibration data for test item-standards are
given in Table 5. The r’ fit was 0.9999 (optimum 1.0000). This reflects the linearity of the
HPLC-system within the calibration range of 0.080 pg/ml to 1.334 pg/ml of the test item.
In conclusion, the partition coefficient of ucb 22060 was determined to be
log Pow = -0.7
using the flask shaking method.