Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
26-10-2017 to 29-01-2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Potassium (1R,3R)-3-[(1Z)-2-chloro-3,3,3-trifluoroprop-1-en-1-yl]-2,2-dimethylcyclopropanecarboxylate and Potassium (1S,3S)-3-[(1Z)-2-chloro-3,3,3-trifluoroprop-1-en-1-yl]-2,2-dimethylcyclopropanecarboxylate
Cas Number:
82597-69-1
Molecular formula:
C9 H10 Cl F3 O2 . K
IUPAC Name:
Potassium (1R,3R)-3-[(1Z)-2-chloro-3,3,3-trifluoroprop-1-en-1-yl]-2,2-dimethylcyclopropanecarboxylate and Potassium (1S,3S)-3-[(1Z)-2-chloro-3,3,3-trifluoroprop-1-en-1-yl]-2,2-dimethylcyclopropanecarboxylate
Test material form:
solid

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
not determinable
Remarks:
The test substance ignited and burned with a flame for ca. 40 seconds before extinguishing, having propagated 10 - 20 mm along the train. It did not propagate combustion fully along the train and the burning time over 200mm could not be determined.

Any other information on results incl. tables

During the screening test, the test substance ignited and burned with a flame for ca. 40 seconds before extinguishing, having propagated 10 - 20 mm along the train. It did not propagate combustion fully along the train and the burning time over 200 mm could not be determined.

Therefore, the full test series are not required.

Applicant's summary and conclusion

Conclusions:
During the screening test, the test substance ignites and propagates combustion very slowly.
In accordance with the criteria of UN Test N.1, the test substance is not classified as a flammable solid.
Executive summary:

During the screening test, the test substance ignites and propagates combustion very slowly.

In accordance with the criteria of UN Test N.1, the test substance is not classified as a flammable solid.