First-aid measures

Description of first aid measures

In case of cutaneous projection

Wash immediately with plenty of water. Remove soiled clothing. If symptoms occur, consult a doctor.

In case of ocular projection

Wash immediately with water or saline for at least 15 minutes, eyelids well apart. Consult a specialist.

In case of inhalation

Transport the person to the fresh air. If she is unconscious, put her in a lateral safety position. Call a doctor.

If swallowed

Immediately call a doctor and show him the label. If the person is unconscious, put him in a lateral safety position.

Rescuers should take precautions to avoid exposure and wear protective equipment.

Most important symptoms and effects, both acute and delayed

No data

Indication of any immediate medical attention and special treatment needed

No data

Fire-fighting measures

Extinguishing media

Appropriate means of extinguishing fires

Carbon dioxide, foam, chemical powder or water spray

Special hazards arising from the subtance or mixture

Specific risks

Release of toxic and corrosive combustion gases in case of fire: hydrogen chloride, carbon oxides.

Advice for firefighters

Qualified firefighters should wear standalone isolating respiratory devices and appropriate protective clothing

Accidental release measures

Personal precautions, protective equipment and emergency procedures

Protection equipment

Wear personal protective equipment mentioned in section 8 before taking action.

Protection and prevention measures

Avoid any contact with the product. Use personal protective equipment (see section 8).

Ensure adequate ventilation.

Precautions for the protection of the environment

Suppress and limit spreading. Do not discharge into the sewer or into the natural environment.

Methods and material for containment and cleaning

Contain the spreading, recover the liquid by pumping and / or absorption on sand or inert absorbent. Put in closed containers properly labeled for later disposal according to section 13.

Wash soil with water and collect the effluent for disposal according to section 13.

Reference to other sections

Exposure control parameters as described in section 8 are applicable in case of accidental dispersion.

Wastes from cleaning must be treated in accordance with the provisions in section 13.

Handling and storage

Precautions for safe handling

Prevention / protection measures

- Safety :

 Keep the product away from any flame or source of sparks. No smoking.

- Health :

 Do not handle with bare hands.

 Do not ingest.

 Avoid contact with eyes.

 Provide adequate ventilation.

 Respect the recommendations of section 8.

- For the environment :

Avoid contamination of the environment directly via surface water or via the soil and indirectly via the water evacuation system.

General advice on hygiene at work

- Do not eat, drink or smoke while working.

- Wash your hands before breaks and at the end of the day.

- If necessary, take a shower at the end of the work.

- Keep personal protections and work clothes clean.

Conditions for safe storage, including any incompatibilities

Technical measures and storage conditions

- Store away from sources of ignition or heat.

- Keep in closed, tightly closed containers in a cool, ventilated place.

Packaging materials

- Store in polyethylene HD or metal containers with polyethylene, glass bottle for samples

- The containers must be carefully closed and labeled.

Specific end use (s)

Internal use as synthesis of intermediate

Sample for analytical characterization tests

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control settings

Indicative limit values:

Ferrocene 10 mg / m3 (INRS, ED 984)

Exposure controls

Technical protection measures

After opening, collective aspiration is recommended to handle the product. Ensure adequate ventilation of the workstations.

Personal protective equipment

In the absence of collective protection and / or exposed staff, the following individual equipment is recommended:

Eye protection:

wear safety glasses.

Skin and body protection:

Wear suitable work clothes.

Hand protection:

Synthetic rubber gloves.

Respiratory protection:

Provide a mask gas cartridge or facial protection with air supply.

Exposure controls related to the protection of the environment

Avoid contamination of the environment directly via surface water or soil and indirectly via water evacuation system.

Stability and reactivity

Reactivity

No data

Chemical stability

The substance is stable under normal conditions of storage and recommended handling (ambient temperature).

Possibility of hazardous reactions

Alkaline metals:

The substance may react with alkaline metals.

Other metals:

The substance may react with alkali earth metals, powdered light metals and oxidants.

Conditions to avoid

Do not expose to a heat source. Thermal decomposition> 200 ° C.

Incompatible materials

Hazardous reactions with alkali metals, alkaline earth metals, powdered light metals, oxidants.

Hazardous decomposition products

Hazardous flue gas release: Hydrochloric acid, chlorinated compounds and carbon oxides by thermal decomposition.

Disposal considerations

Waste / unused product

- Waste disposal is only possible in centers authorized by the competent administrative authority,

- Waste must be treated under the conditions authorized by the regulations,

- Do not discharge into the sewer or in the natural environment.

Contaminated packaging

- soiled packaging must be disposed of in the same way as the product itself.