Administrative data

First-aid measures

Emergency measure - Inhalation: Immediately remove to fresh air; consult a physician if

irritating symptoms develop and persist.

Emergency measure - Eyes: Immediately rinse eyes with running water and seek medical

advice.

Emergency measure - Skin: Wash immediately with plenty of water and soap.

Emergency measure - Ingestion: Only as long as the patient is fully conscious: Wash mouth

and have the victim drink copious amount of water; consult

the physician if feeling sick and show the label.

Fire-fighting measures

Recommended extinguishing agent: All

Product arising from burning: Carbon dioxide, carbon monoxide, nitrogen oxides.

Product determined by test: N

Protective equipment: Fire-fighters should wear protective clothing including self

contained breathing apparatus.

Accidental release measures

Emergency measures in case of spillage: Sweep up spilled material; try to minimize formation of

dust; material must not be released into sewers, drains or

wells.

Handling and storage

Handling: Do not breathe dust. Avoid contact with skin. After

finishing work wash hands and face with water and soap. Use

dust mask, safety glasses, rubber gloves and protective

suit.

Storage: Avoid formation of dust. Take precautionary measures against

static discharges. Keep dry. Store in a dark place. Maximum

storage temperature: 8 °C.

Packaging of the substance and or preparation: Not applicable.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Transport under the above mentioned storage conditions.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

All equipment and protective garments must be either decontaminated or properly contained

for disposal before leaving the area. All areas where this material is handled must be labelled

as a Designated Area. Access to Designated Areas shall be limited to authorised personnel

only.

The personal protective measure may be adapted appropriately when working in closed

systems or under laboratory conditions.

Regular cleaning of equipment, work area and clothing.

No open handling without using reliable equipment. One technical barrier between substance

and employee resp. environment.

Equipment and protective garments must either be decontaminated or properly contained for

disposal before leaving the area.

Designated washing, changing and shower facilities must be available.

Disposable protective equipment is to be decontaminated before removal (decontamination

shower).

Restricted and controlled access for trained personnel only.

Internal working procedures available to personnel covering personal hygiene,

decontamination /cleaning, consideration of worst case incidents, spills, emergency, alarms,

waste disposal and maintenance.

Personnel comprehensively instructed, highly trained and experienced. Regular refresher

training established including appropriate record keeping.

Respiration : Full face mask (EN136)

Filter : P3 (EN143)

Eye : Yes, by face mask

Hand : Normal length chemical-mechanical-resistant gloves (EN374/EN388)

worn over disposable gloves

Glove Material : Nitrile

Breakthrough time: > 480 min

Thickness: 0.2 mm

Additional protection : Disposable dust-proof suit (EN465, type 4) worn over long underwear

Disposable boot covers, conductive

Stability and reactivity

Danger other than fire: Dust explosion is possible.

Chemical reaction with water: None.

Dust explosion: Internal screening test gave positive results as is to be

expected for organic powders.

Dust explosion determined by test: Y

Disposal considerations

Industry - Possibility of recovery/recycling: No practical method of recovery/recycling is known.

Industry - Possibility of neutralisation: Not known.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: National regulations must be observed.

Industry - Possibility of destruction - water purification: Not recommended.

Industry - Possibility of destruction - other: Not recommended.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable