Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25 January 2001 - 29 January 2001
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Study conducted in compliance with agreed protocols, with no or minor deviations from the standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results. The study report was conclusive, done to a valid guideline and conducted under GLP conditions.

Data source

Referenceopen allclose all

Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7000 (pH)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
1-[3,5-dichloro-2-fluoro-4-(1,1,2,3,3,3-hexafluoropropoxy)phenyl]-3-(2,6-difluorobenzoyl)urea
EC Number:
601-779-5
Cas Number:
121451-02-3
Molecular formula:
C17H7Cl2F9N2O3
IUPAC Name:
1-[3,5-dichloro-2-fluoro-4-(1,1,2,3,3,3-hexafluoropropoxy)phenyl]-3-(2,6-difluorobenzoyl)urea
Test material form:
solid

Results and discussion

pH value
Key result
pH value:
6.31
Temp.:
23.6 °C
Concentration:
>= 0.95 - <= 0.97 other: % w/w

Any other information on results incl. tables

Table 1: pH Results

Aliquot 1

Aliquot 2

Overall Average

Reading 1

6.20

Reading 1

6.36

6.31

Reading 2

6.22

Reading 2

6.44

Average

6.21

Average

6.40

Applicant's summary and conclusion

Conclusions:
Under the conditions of the test, the pH of the test material was determined to be 6.31.
Executive summary:

The pH of the test material was determined in a study performed under GLP conditions and in line with the standardised guideline EPA OPPTS 830.7000.

The pH of two solutions, at concentrations of 0.95 and 0.97 % w/w, were measured in duplicate using a pH meter and the average reported. Under the conditions of the test, the pH of the test material was determined to be 6.31.