Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Principles of method if other than guideline:
The test was performed according to the SOP - STR 071 protocol.Laser light scattering.The particle size distribution was analyzed using the Mastersizer 2000 tool, which uses the technique of laser diffraction to measures the size of particles. It measures the intensity of light scattered as a laser beam passes through a dispersed particulate sample. This data is then analyzed to calculate the size of the particles that created the scattering pattern. The sample was dispersed, stirred and ultrasonicated prior the analytical characterisation by light scattering.
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
ca. 15.9 µm
St. dev.:
2
Percentile:
D50
Mean:
ca. 34.6 µm
St. dev.:
5
Percentile:
D90
Mean:
ca. 66.8 µm
St. dev.:
5
Conclusions:
The substance particle size distribution was measured by light scattering and the results are D10 = 15.9 µm, D50 = 34.6 µm and D90 = 66.8 µm.
Executive summary:

The substance particle size distribution was measured by light scattering and the results are D10 = 15.9 µm, D50 = 34.6 µm and D90 = 66.8 µm.

Description of key information

D10 = 15.9 µm
D50 = 34.6 µm
D90 = 66.8 µm

Additional information

The particle size distribution was determined by light scattering (REACH&Colours Kft, 2015) and resulted to have the following parameters D10 = 15.9 µm, D50 = 34.6 µm and D90 = 66.8 µm.